期刊文献+

猪离体心脏冠状动脉的MSCT造影 被引量:7

Coronary Angiography of in vitro Porcine Heart Using MSCT
下载PDF
导出
摘要 目的通过对猪离体心脏冠状动脉进行多层螺旋CT(MSCT)造影成像,探索离体心脏血管造影技术的具体操作方法及参数。方法应用自主改装的血管造影装置,分别将脂溶性和水溶性对比剂以不同灌注量(50、60、70mL)和不同灌注-成像时间间隔(5、10、20min)灌注猪离体心脏冠状动脉,进行MSCT扫描和三维图像效果比较,由2名放射科医生对各组的造影成像效果进行评估和记录,并对结果进行统计学分析。结果脂溶性对比剂对冠状动脉周围脂肪造成浸润和破坏而影响造影成像效果,而水溶性对比剂未出现类似结果。灌注-成像时间间隔为5min,且灌注量为60mL和70mL时造影成像质量最佳。结论本研究的血管造影参数为后期开展尸体在体心脏冠脉造影奠定基础。 Objective To establish standardized methods and parameters of the isolated heart coronary an- giography through the experiment of in vitro porcine heart by MSCT. Methods Based on different perfu- sion volume (50, 60 and 70mL) and different perfusion-imaging time (5, 10 and 20min), the in vitro porcine coronary artery was injected liposoluble and water-soluble contrast agents using remodel angiog- raphy equipment and scanned by MSCT. And the 3D image results were compared. The images were recorded and evaluated by 2 radiologists and analyzed by statistical soft-ware. Results Liposoluble con- trast agent affected the images by damaging and infiltrating the fats around the coronary artery, while the water-soluble contrast agent didn't affect the images. The groups with 60 mL or 70 mL perfusion and 5 min perfusion-imaging time had the best images. Conclusion The suitable parameters of the an- giography lay the foundation of postmortem coronary angiography.
出处 《法医学杂志》 CAS CSCD 2014年第5期321-324,336,共5页 Journal of Forensic Medicine
基金 国家自然科学基金资助项目(81401559) 中央级科研院所科研专项(GY2012S-1) "十二五"国家科技支撑计划项目(2012BAK16B02) 上海市法医学重点实验室资助项目(13DZ2271500)
关键词 法医病理学 血管造影 虚拟解剖 对比剂 冠状动脉 forensic pathology angiography virtopsy contrast agents coronary
  • 相关文献

参考文献13

  • 1Dirnhofer R, Jackowski C, Vock P, et al. VIR- TOPSY: minimally invasive, imaging-guided virtual autopsy[J]. Radiographics, 2006,26 (5) : 1305-1333.
  • 2李果珍.115CT诊断学[M].北京:中国科学技术出版社.2005.
  • 3万雷,魏华.一种尸体血管造影装置:中国,0527276.6[P].2014.03.12.
  • 4Schoenmackers J. Technic of postmortem angiography with reference to related methods of postmortem blood vessel demonstration[J]. Ergeb Allg Pathol Pathol Anat, 1960,39:53-151.
  • 5Ross S, Spendlove D, Bolliger S, et al. Postmortem whole-body CT angiography: evaluation of two con- trast media solutions[J]. AJR Am J Roentgenol,2008, 190(5) : 1380-1389.
  • 6Grabherr S, Gygax E, Sollberger B, et al. Two-step postmortem angiography with a modified heart-lung machine: preliminary results[J]. AJR Am J Roentgenol, 2008,190(2) :345-351.
  • 7Grabherr S, Doenz F, Steger B, et ol. Multi-phase post-mortem CT angiography: development of a stan- dardized protocol[J]. Int J Legal Med,2011,125 (6) : 791-802.
  • 8Ruder TD, Ketterer T, Preiss U, et al. Suicidal knife wound to the heart: challenges in reconstruct- ing wound channels with post mortem CT and CT-angiography[J]. Leg Med (Tokyo),2011,13 (2): 91-94.
  • 9Roberts ISD, Benamore RE, Peebles C, et al. Di- agnosis of coronary artery disease using minimally invasive autopsy: evaluation of a novel method of post-mortem coronary CT angiography[J]. Clin Radi- ol,2011,66(7) :645-650.
  • 10Spalteholz W. Anatomischer Teil[J]. Dtsch MedWochenschr,1907,20:792-795.

同被引文献49

  • 1高振强,马建军,牛琛,罗利,杨德猛,李向前,冯艳飞,王琦,郭志坤.家猪右冠状动脉解剖学观测[J].新乡医学院学报,2007,24(6):602-603. 被引量:3
  • 2谭团团,马建军,杨德猛,罗利,郑宇浩,高振强,李向前,冯艳飞,岳学强.家猪心脏左冠状动脉形态学观测[J].新乡医学院学报,2008,25(1):78-80. 被引量:5
  • 3Zhou S, Wan L, Shao Y, et al. Detection of aortic rupture using post-mortem computed tomography and post-mortem computed tomography angiography by cardiac puncture[J]. Int J Legal Med,2016,130(2): 469-474.
  • 4Aghayev E, Thali MJ, Sonnenschein M, et al. Fa- tal steamer accident; blunt force injuries and drown- ing in post-mortem MSCT and MRI[J]. Forensic Sci Int,2005,152 (1) : 65-71.
  • 5Hillewig E, Aghayev E, Jackowski C, et all. Gas embolism following intraosseous medication applica-tion proven by post-mortem multisliee computed to- mography and autopsy[J]. Resuscitation,2007,72 (1) : 149-153.
  • 6Smith M, Trummel DE, Dolz M, et a/. A simpli- fied method for postmortem coronary angiography using gastrograffin[J]. Arch Pathol Lab Med, 1999, 123 (10) : 885-888.
  • 7Tajima ~, Takagi R, Kominato Y, et a/. A case of iatrogenic cerebral infarction demonstrated by post- mortem cerebral angiography[J]. Leg Med (Tokyo), 2007,9(6) :326-329.
  • 8Inokuchi G, Yajima D, Hayakawa M, et al. The utility of postmortem computed tomography selective coro- nary angiography in parallel with autopsy[J]. Foren- sic Sci Med Pathol,2013,9(4):506-514.
  • 9Roberts IS, Benamore RE, Peebles C, et al. Techni- cal report: diagnosis of coronary artery disease using minimally invasive autopsy: evaluation of a novel method of post-mortem coronary CT angiography[J]. Clin Radiol, 2011,66 (7) : 645-650.
  • 10Grabherr S, Grimm J, Dominguez A, et al. Advances in post-mortem CT-angiography[J]. Br J Radiol,2014, 87(1036) :20130488.

引证文献7

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部