摘要 目的建立阿昔洛韦片溶出度的高效液相色谱法(HPLc)测定方法。方法色谱柱为依利特BDSC18150mm×4.6mmμm,柱温:30℃,流动相为水:甲醇(90:10),检测波长254nm,流速为1.0ml。·min-1,进样体积:20μL,结果阿昔洛韦片在4.664~93.28μg·mL-1的浓度范围内呈良好的线性关系(r=0.9999),平均回收率为99.8%(n=9)RSD为0.2%。结论该方法高效,准确,灵敏度高,重现性好,可作为阿昔洛韦片的溶出度的检测方法。 OBJECTIVE To estabhsh a HPLC method for dissolution of Aciclovir tablets. METHODS Hyper- sil BDS C18 column ( 150mm × 4.6mm, 5 μm) was used with a mobile phasecomposed of methanol-water ( 10: 90 ) at the flow rate of 1.0mL · min-1. The detection wavelength was 254nm and the temperature of the column was 30℃The injection volume was 20μL. RESULTS The calibration curve of Aciclovir was linear in the range of 4. 664 - 93. 251μg · mL-1 (r =0. 999 9). The average recover)" was 99. 8% with RSD of 0. 2% ( n = 9). CONCLUSION Compared with the standard method, the results are satisfactory, and the method is effective and accurate, which could be used for the determination of dissolution of Aciclovir tablets.
作者 吴美芳 黄芳
出处 《海峡药学》 2014年第10期72-74,共3页 Strait Pharmaceutical Journal
关键词 阿昔洛韦片 溶出度 高效液相色谱法 Aciclovir tablets Dissolution HPLC