期刊文献+

两种园林用FDR土壤水分传感器的精度校正

Accuracy calibration of two FDR soil moisture sensors used in urban landscape
下载PDF
导出
摘要 利用质地差异较大的园土及草炭∶陶粒∶园土=3∶1∶1(体积比)的混合基质对2种土壤水分频域反射仪(FDR)进行了室内标定.结果显示,在目前园林应用的测量精度内,土壤质地对两种FDR土壤水分传感器的测量影响不显著,但FDR测量值较烘干法明显偏高,校正斜率介于0.68~0.70之间.相关分析表明FDR测量值与真实值之间有极显著的相关性,相关系数大于0.97.利用获得的线性函数进行校正,校正后的土壤水分值与采用传统的烘干称重法测得的值相符.基于以上结果,FDR土壤水分传感器能准确、快速测定土壤含水量,在城市园林节水灌溉管理中发挥重要作用. In this study two FDR soil moisture sensors were calibrated using two different types of medium,garden soils and mixed medium composed ofpeat,ceramisite,and garden soil in a 3 ∶ 1 ∶ 1 ratio (volumetric rate).The results showed in the requiredrange of measurement accuracy,the measurement result using FDR soil moisture sensors was not affected by soil texture,however the value was greater than the actual soil water content obtained through drying method.And it was found that there was a significant linear relationship between measured and actual water content relationship with the correlation coefficient exceeding 0.97,and the slope was between 0.68-0.70.After calibrated though this mathematical function,the measured value obtained using FDRsoil moisture sensor,agreed well with the actual water content.Based on the above results,FDR soil moisture sensor can measure the soil water content exactly and rapidly,playingan important role in the water conservation of urban landscape irrigation management.
出处 《北京农学院学报》 2014年第4期73-77,共5页 Journal of Beijing University of Agriculture
基金 "十二五"国家科技支撑计划课题"低碳宜居型建筑室外绿地建设技术研究"(2013BAJ02B01) 北京市留学人员科技活动择优资助启动项目"基于土壤水分入渗规律的公园古树灌溉模型的建立与应用" 北京市公园管理中心科技课题"北京市古树(大树)试验站的建立及油松 白皮松大树根系生长规律研究"
关键词 园林 FDR 土壤水分传感器 校正 landscape FDR soil moisture sensors accuracy calibration
  • 相关文献

参考文献10

  • 1刘玉华,史纪安,韩清芳,贾志宽,任鸿远,吴新卫.中子仪测定苜蓿田土壤含水量的标定研究[J].干旱地区农业研究,2007,25(2):115-119. 被引量:6
  • 2周凌云,陈志雄,李卫民.TDR法测定土壤含水量的标定研究[J].土壤学报,2003,40(1):59-64. 被引量:93
  • 3Roth K, Malicki M A, Plagge R. Empirical evaluation of the relation ship between soil dielectric constant and volumetric water content as the basis for calibrating soil moisture measurements by TDR[J]. Journal oi" Soil Science, 1992, 43(1):1-13.
  • 4张宪,姜晶,王劲松.基于FDR技术的土壤水分传感器设计[J].自动化技术与应用,2011,30(11):61-65. 被引量:16
  • 5郭卫华,李波,张新时,王仁卿.FDR系统在土壤水分连续动态监测中的应用[J].干旱区研究,2003,20(4):247-251. 被引量:67
  • 6Mccoy E L, Mccoy K R. Simulation of putting-green soil water dy namics: Implications for turfgrass water use[J]. Agricultural Water Management, 96(3): 405-414.
  • 7Topp G C, Davis J L, Annan A P. Electromagnetic determination of soil water content: measurement in coaxial transmission lines[J]. Wa- ter Resources Research, 1980, 16:574-582.
  • 8Seyfried M S, Murdock M D. Response of a new soil water sensor to variable soil, water content, and temperature[J]. Soil Science Society of America Journal, 2001, 65(1):28-34.
  • 9Saito T, Fujimaki H, Yasuda H, et al. Calibration of temperature effect on dielectric probes using time series field data[J]. Vadose Zone Journal, 2013, 12(2): 184-189.
  • 10Irmak s, Irmak A. Performance of frequency-domain reflectometer, ca- pacitance, and psuedo-transit time-based soil water content probes in four coarse-textured soils [J]. Applied Engineering in Agriculture, 2005, 21(6) :999-1008.

二级参考文献24

共引文献171

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部