期刊文献+

经皮冷冻球囊导管消融治疗阵发性心房颤动患者的术中护理 被引量:10

Cryoballoon ablation for paroxysmal atrial fibrillation:intra-operative nursing care
下载PDF
导出
摘要 对6例阵发性心房颤动患者行经皮冷冻球囊导管消融术,均顺利完成手术,术中及术后未发生膈神经麻痹等手术相关并发症。全面了解冷冻球囊导管消融手术过程,做好术前准备,熟悉各种物品及设备的使用方法和注意事项;术中给予患者心理支持,了解不良症状发生情况,严密观察生命体征,监测活化凝血酶原时间,加强气胸、急性心脏压塞、膈神经麻痹、血管迷走神经反射、疼痛、咳嗽等症状的监护,是确保手术顺利完成的重点措施。
出处 《护理学杂志(综合版)》 CSCD 2014年第11期27-29,共3页 Journal of Nursing Science
  • 相关文献

参考文献7

  • 1Ahmed H, Neuzil P, Skoda J, et al. The permanency ofpulmonary vein isolation using a balloon cryoablation catheter[J]. J Cardiovasc Electrophysiol, 2010, 21 (7) : 731-737.
  • 2Khairy P, Dubuc M. Transcatheter cryoablation part I: pre- clinical experience[J]. Pacing Clin Electrophysiol, 2008,31 (1) :112-120.
  • 3Lemola K, Dubuc M, Khairy P. Transcatheter cryoabla- tion part II: clinical utility[J]. Pacing Clin Electrophy- siol,2008,31(2) :235-244.
  • 4Sarabanda A V, Bunch T J, Johnson S B, et al. Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system[J]. J Am Coll Cardiol,2005,46(10):1902-1912.
  • 5乔宇,郭炜,姚焰,张澍,牛国栋.用于心房颤动肺静脉隔离的冷冻消融器械[J].心血管病学进展,2013,34(3):306-310. 被引量:4
  • 6Kojodjojo P, OrNeill M D, Lim P B, et al. Pulmonary venous isolation by antral ablation with a large eryobal- loon for treatment of paroxysmal and persistent atrial fi- brillation: medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofre- quency ablation[J]. Heart, 2010,96 (17) :1379-1384.
  • 7Andrade J G, Khairy P, Ouerra P G, et al. Efficacy and safety of cryoballoon ablation for atrial fibrillation:a sys- tematic review of published studies[J].Heart Rhythm, 2011,8(9) :1444-1451.

二级参考文献22

  • 1Haissaguerre M, JaYs P, Shah DC, et al. Spontaneous initiation of atrial fibrilla- tion by eetopic beats originating in the pulmonary veins [ J ]. N Engl J Med, 1998, 339(10) :659-666.
  • 2Chen SA, Hsieh MH, Tai CT, et al. Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [ J ]. Circula- tion, 1999, 100(18):1879-1886.
  • 3Zhou S, Chang CM, Wu TJ, et al. Nonreantrant focal activations in pulmonary veins in canine model of sustained atrial fibrillation [ J ]. Am J Physiol Heart Cire Physiol,2002, 283(3) :H1244-H1252.
  • 4Arora R, Verheule S, Scott L, et al. Arrhythmoganic substrate of the pulmonary veins assessed by high-resolution optical mapping[ J ]. Circulation, 2003, 107 (13) :1816-1821.
  • 5Calkins H, Bmgada J, Packer DL, et al. HRS/EHRA/ECAS expert Consensus Statement on catheter and surgical ablation of atrial fibrillation: recommenda- tions for personnel, policy, procedures and follow-up. A report of the Heart Rhythin Society (HRS) Task Force on catheter and surgical ablation of atrial fi- brillation[J]. Heart Rhythm, 2007, 4(6) :816-861.
  • 6Halssaguerre M, Shah DC, JaYs P, et al. Electrophysiological breakthroughs from the left atrium to the pulmonary veins[ J ]. Circulation, 2000, 102 (20) : 2463 -2465.
  • 7Oral H, Knight BP, Tada H, et al. Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation [ J ]. Circulation, 2002, 105 (9) : 1077-1081.
  • 8Riccardi R, Gaita F, Caponi D, et al. Pereutaneous catheter eryothermal abla- tion of atriovantricular nodal reentrant tachycardia: efficacy and safety of a new ablation technique [ J ]. Ital Heart J, 2003, 4 ( 1 ) :35 -43.
  • 9Gaita F, Haissaguerre M, Giustetto C, et al. Safety and efficacy of cryoablation of accessory pathways adjacent to the normal conduction system [ J ]. J Cardio- vase Electrophysiol, 2003, 14 ( 8 ) :825 -829.
  • 10Dubuc M, Roy D, Thibault B, et al. Transvenous catheter ice mapping and cryoablation of the atrioventricular node in dogs[J]. Pacing Clin Electrophysi- ol, 1999, 22 (10) : 1488-1498.