介绍因为氢氮比严重失调及催化剂暂时中毒导致氨合成塔垮温的经过,分析原因后,采取措施恢复生产,并介绍了日常生产中的预防措施。
Describe the ratio of H/N serious imbalance and the catalyst temporary poisoning leading to the ammonia reactor collapsing temperature. After analyzing the cause and taking treatment measures, operation is normal. The preventive measures in daily production is also described.