期刊文献+

Dose rate distribution of photoneutrons in an ID beamline of SSRF: simulations and measurements 被引量:2

Dose rate distribution of photoneutrons in an ID beamline of SSRF: simulations and measurements
下载PDF
导出
摘要 Photoneutrons, emitted by means of photonuclear interactions when gas bremsstrahlung interacts with beamline components, can be another potential radiation source needed to be considered for shielding design and dose assessment of beamline. In this paper, simulations and measurements of photoneutrons dose rate at beamline BL09 U are carried out when Shanghai Synchrotron Radiation Facility(SSRF) running at Top-up mode(3.5 GeV, 235 mA). A geometry model is constructed for the beamline BL09 U with considerations of the scattering process of the major optical components. The model is compiled into Monte Carlo simulation code FLUKA to calculate photoneutron dose distribution. Measurements of the photoneutrons dose rate were performed by using Environmental Neutron Monitor(ENM). Observation points were arranged uniformly along the inside and outside of the optical enclosure(OE) of BL09 U. The calculation results agree with experiments within the measurements uncertainties. It is verified that photoneutrons dose simulation is reliable. The simulation and measurement methods can be applied to evaluate the neutron dose level of other beamline stations, and provide references for the shielding design of the beamlines at SSRF in the near future. Photoneutrons, emitted by means of photonuclear interactions when gas bremsstrahlung interacts with beam- line components, can be another potential radiation source needed to be considered for shielding design and dose assessment of beamline. In this paper, simulations and measurements of photoneutrons dose rate at beam- line BL09U are carried out when Shanghai Synchrotron Radiation Facility (SSRF) running at Top-up mode (3.5 GeV, 235 mA). A geometry model is constructed for the beamline BL09U with considerations of the scattering process of the major optical components. The model is compiled into Monte Carlo simulation code FLUKA to calculate photoneutron dose distribution. Measurements of the photoneutrons dose rate were per- formed by using Environmental Neutron Monitor (ENM). Observation points were arranged uniformly along the inside and outside of the optical enclosure (OE) of BL09U. The calculation results agree with experiments within the measurements uncertainties. It is verified that photoneutrons dose simulation is reliable. The simula- tion and measurement methods can be applied to evaluate the neutron dose level of other beamline stations, and provide references for the shielding design of the beamlines at SSRF in the near future.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第5期1-5,共5页 核技术(英文)
关键词 中子测量 SSRF 剂量评估 光束线 仿真 速度分布 上海同步辐射装置 蒙特卡罗模拟 Gas bremsstrahlung, Photoneutron, Monte Carlo simulation, Radiation dose, Synchrotron radiation facility
  • 相关文献

参考文献10

  • 1Rindi A. Health Phys, 1982, 42: 187-193.
  • 2Pisharody M, Job P K, Magill S, et al. Nucl Instrum Meth A, 1997, 401: 442-462.
  • 3Pisharody M, Semones E, Job P K. Nucl Instrum Meth A, 1999 430: 542-558.
  • 4Sheu R J, Wang J P, Sheu R D, et al. Nucl Instrum Meth B 2004, 217: 555-563.
  • 5Asai J and Hirayama H. Nucl Instrum Meth A, 2004, 527: 264- 272.
  • 6Liu J C, Nerson W R, Kase K R, et al. Radiat Prot Dosim,1997, 70: 49-54.
  • 7Fasso A, Ferrari A, Sala P R. Electron-photon transport in FLUKA: status, Proceedings of the Monte Carlo 2000 Con-ference, Lisbon, Oct. 23-26, 2000.
  • 8Fasso A, Ferrari A, Ranft J, et al. FLUKA: status and prospec- tive for hadronic applications, Proceedings of the Monte Carlo 2000 Conference, Lisbon, Oct. 23-26, 2000.
  • 9Pelliccioni M. Radiat Prot Dosim, 2000, 88: 279-297.
  • 10Li J P, Tang Y L, Liu S D, et al. Radiat Prot Dosim, 1996, 67: 179-185.