摘要
采用高效液相色谱-串联质谱(HPLC-MS/MS)方法进行了河鲀鱼肝脏中河鲀毒素(Tetrodotoxin,TTX)含量的快速检测研究。河鲀鱼肝脏样品用1%乙酸甲醇溶液超声提取2次,正己烷脱脂后用C18和石墨化碳黑(GCB)混合吸附剂净化,冷冻高速离心,上清液经聚四氟乙烯-尼龙复合膜过滤;TSK-gel Amide-80 3μm色谱柱分离,乙腈和0.15%乙酸(含10mmol/L乙酸铵)溶液为流动相梯度洗脱进行HPLC-MS/MS分析。外标法定量测定。方法检出限为40μg/kg,在50~1 000μg/kg范围内线性关系良好。在河鲀鱼肝脏中添加50,75,100μg/kg TTX进行重复性试验,回收率在79.2%~105.3%之间,相对标准偏差(RSD)不大于9.0%(n=6)。本方法准确、灵敏、实用,节约时间和试剂,操作简单,易重现,满足目前对河鲀鱼肝脏中TTX含量快速定量检测的技术要求。
A simple, rapid, sensitive and cheaper high performance liquid chromatography-tandem qua- drupole mass spectrometry( HPLC-ESI-MS/MS) method was developed for the determination of Tetro- dotoxin(TTX)in Fugu liver. The analytes were extracted from fugu liver samples by acetic acid metha- nol(1 : 99, V/V), defatted by hexane then purified by freezed centrifugation and mixture of Cleanert PestiCarb and C18 sobent. The analyte was determined by HPLC-MS/MS using acetonitrile and water (0. 15 % acetic acid and 10 mmol/L ammonium acetate) as the mobile phase by gradient elution. The quantification was performed with the external standard method. The curve of calibration was linear within the range of 50-1000. 0μg/kg and the detection limit was 40μg/kg. Recoveries of spiked tetro- dotoxin at level of 50, 75, 100μ/kg were beteen 79.2 % and 105.3% with relative standard deviation (RSD)was less than 9. 0 %(n=6). The method has good accuracy, sensitivity, repeatability, simplici- ty, fast and economy to meet practical analysis of TTX in fugu liver samples.
出处
《中国海洋大学学报(自然科学版)》
CAS
CSCD
北大核心
2014年第11期52-58,66,共8页
Periodical of Ocean University of China
基金
国家自然科学基金创新研究群体项目(41221004)
山东检验检疫局科技项目(SK201228)资助
关键词
QUECHERS
液相色谱-质谱/质谱
河鲀毒素
河鲀鱼肝脏
快速检测
QuEChERS~ high performance liquid chromatograph tandem quadrupole mass spectrome-try(HPLC-MS/MS)
tetrodotoxin(TTX)
fugu liver
rapid determination