多排螺旋CT剂量效率的体模研究 被引量:2

Phantom Study of Dose Efficiency of MDCT
下载PDF
导出
摘要 目的:研究CTDI100表征CT检查所致辐射剂量的准确性。方法使用长杆电离室测量不同准值宽度、螺距以及管电压下体模内剂量分布曲线并计算CT剂量效率。结果 CT剂量效率范围为79%~94%,其中,中心位置的CT剂量效率范围为79%~87%,边缘4个位置的CT剂量效率范围为79%~94%,加权CT剂量效率范围为82%~90%。准直宽度与螺距越大,CT剂量效率越低;CT剂量效率受管电压影响不明显。结论CTDI100与CTDI∞之间存在一定差异,CTDI100、CTDIw表征CT检查所致辐射剂量的准确度随准直宽度和螺距的增大而降低。 Objective To explore the accuracy ofCTDI100 in evaluating radiation dose of CT examination. Methods Dose distribution curves of the phantom under the conditions of different collimation widths, pitches and tube voltages were measured with long-pole ionization chamber and thenCTDI100 and CTDI∞were calculated to evaluate the dose efficiency of CT examination.Results The range of CT radiation dose efifciency was 79%~94%. The range of CT radiation dose efifciency located at the center was 79%~87% and that of CT radiation dose efifciency located at margins was 79%~94% while that of weighted CT radiation dose efifciency was 82%~90%. The longer the collimation widths and pitches, the lower the CT radiation dose efifciency. The inlfuence of tube voltages on CT radiation dose efifciency was unconspicuous.Conclusion There were certain differences betweenCTDI100 andCTDI∞ in evaluating radiation dose of CT examination. The accuracy ofCTDI100 andCTDIw in evaluating radiation dose of CT examination would be decreased as the increasement of collimation widths and pitches.
出处 《中国医疗设备》 2014年第11期41-42,71,共3页 China Medical Devices
基金 国家自然科学基金项目资助(81372923) 国家科技支撑计划课题(2011BAI02B02)
关键词 CTDI100 多排螺旋CT 准直宽度 CT剂量效率 CTDI100 MDCT collimation widths CT radiation dose efifciency
  • 相关文献

参考文献9

  • 1徐桓,赵庆军.固体切片探测器CT-SD16在CT剂量测量中的应用与研究[J].中国医学装备,2010,7(2):17-20. 被引量:7
  • 2McCoUough CH.It is time to retire the computed tomography dose index (CTDI) for CT quality assurance and dose optimization[J].Med Phys,2006,33(5):1190-1191.
  • 3Perisinakis K,Damilakis J,Tzedakis A,et al.Determination of the weighted CT dose index in modem multi-detector CT scanners[J].Phys Med Biol,2007,52(21):6485-6495.
  • 4Boone JM.The trouble with CTD100[J].Med Phys,2007,34(4):1364- 1371.
  • 5Shope TB,Gagne RMJohnson GC.A method for describing the doses delivered by transmission x-ray computed tomography[J]. Med Phys,1981,8(4):488-495.
  • 6白玫,郑钧正.多排(层)螺旋CT的辐射剂量表达及其影响因素探讨[J].辐射防护,2008,28(1):1-12. 被引量:66
  • 7Ruan C,Yukihara EG,Clouse WJ,et al.Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology[J].Med Phys,2010,37(7):3560-3568.
  • 8Li X,Zhang D,Liu B.Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms[J].Med Phys, 2013,40(8) :081914.
  • 9张冠石.医护人员的放射防护[J].中国医疗设备,2013,28(5):15-16. 被引量:8

二级参考文献47

共引文献76

同被引文献36

  • 1王晓峰,彭明辰.关于多排螺旋CT剂量的探讨[J].医疗设备信息,2004,19(12):23-25. 被引量:20
  • 2杨珂,吴建,李福生,陈英民.CT剂量指数(CTDI)的使用[J].中国辐射卫生,2005,14(1):76-77. 被引量:5
  • 3郑钧正.加强医疗照射防护的重点工作[J].中华放射医学与防护杂志,2005,25(2):105-106. 被引量:44
  • 4郭洪涛,刘勇,袁淑华.CT剂量指数(CTDI)测量研究[J].中国测试技术,2007,33(4):33-36. 被引量:33
  • 5McCollough CH.It is time to retire the computed tomography dose index(CTDI)for CT quality assurance and dose optimization[J].Med Phys, 2006,33(5): 1190-1191.
  • 6Perisinakis K,Damilakis J,Tzedakis A,et al. Determination of the weighted CT dose index in modern multi-detector CT scanners[J].Phys Med Biol, 2007,52(21) :6485-6495.
  • 7Boone JM.The trouble with CTDIoo[J].Med Phys, 2007,34(4): 1364-1371.
  • 8Shope TB,Gagne RM,Johnson GC.A method for describing the doses delivered by transmission x-ray computed tomography[J].Med Phys, 1981,8(4): 488-495.
  • 9Ruan C, Yukihara EG, Clouse WJ,et al. Deter- mination of multislice computed tomography dose index(CTDI)using optically stimulated luminescence technoloay[J]. Ivied Phys, 2010,37(7): 3560-3568.
  • 10Li X,Zhang D,Liu B. Caloalations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms[J]. Med Phys, 2013,40(8): 081914.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部