摘要
结合首都机场T3航站楼EPS(应急电源)柜中的部分蓄电池出现鼓包和水迹的原因案例,重点阐述更换电池前应考虑的因素,在更换过程中应注意的事项和更换完电池要完善的工作。
This paper focuses on the factors that should be considered battery work of before replacing the batteries and finish replacement to improve. Part of the batteu, cabinet drum kits and water stains reason case of Capital Airport T3 Terminal EPS emergency power supply has be combined in this paper.
出处
《智能建筑与城市信息》
2014年第11期71-72,共2页
Intelligent Building and City Infomation
关键词
EPS
蓄电池组
安时量
安装
检测
调试
互投装置
EPS
battery pack
Ampere-hour quantity
installation
testing
commissioning
each switch device