期刊文献+

基于不同结构分类的金属氧化物避雷器电气特性对比分析 被引量:2

Comparative Study and Analysis of Electrical Characteristics for Metal-oxide Surge Arresters Based on Various Structural Classifications
下载PDF
导出
摘要 总结金属氧化物避雷器电气特性的考核指标体系:额定电压Ur、持续运行电压Uc、标称放电电流In、保护水平与绝缘配合系数Ks等,并基于不同的结构特征分别进行了说明。以10 k V配电系统为例,测算与校验了2种结构特征(无间隙与带串联间隙)金属氧化物避雷器的主要特性参数;结合测算结果与实际工程案例,针对金属氧化物避雷器工作中发生爆炸等安全事故的原因进行分析,并提出了合理化建议,促进中压电力系统中金属氧化物避雷器的正确使用,并进一步提高对电气设备过电压的有效保护。 In the paper, an index system for electrical characteristics of metal-oxide surge arresters is systematically summarized, which contains rated voltage ( Ur ), continuous operating voltage ( Uc ), nominal discharge current ( In ), overvoltage protection and insulation coordination coefficient (Ks ) , which are described based on various structural functions. Also, taking 10 kV power distribution system as an example, the main parameters of metal-oxide surge arresters without gaps and metal-oxide surge arresters containing series gapped structures are measured and checked. Combined the results with actual engineering cases, aiming at the safety accidents ( such as explosion and etc. ) in the use of metal-oxide surge arresters, the paper analyzes the causes and puts forward reasonable suggestions to promote the correct use of metal-oxide surge arresters in MV power system, and further to improve its effective utilization of electrical equipment overvoltage protection.
出处 《西华大学学报(自然科学版)》 CAS 2014年第6期16-19,41,共5页 Journal of Xihua University:Natural Science Edition
基金 教育部重点实验室学术成果培育项目"流体及动力机械"(SBZDPY-11-15) 四川省教育厅自然科学重点项目(11ZA280)
关键词 无间隙金属氧化物避雷器 带串联间隙金属氧化物避雷器 电气特性 结构分类 对比分析 metal-oxide surge arrester without gap metal-oxide surge arrester containing series gapped structure electrical characteristic structural classification comparative study and analysis
  • 相关文献

参考文献10

二级参考文献13

共引文献17

同被引文献6

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部