摘要
目的:探讨GEB-600(高尔宝)尿液分析仪检测红细胞、白细胞酯酶(LEU)、尿葡萄糖(GLU)的效果。方法:收集临床门诊患者新鲜尿液680份,用尿液分析仪检测红细胞、LEU和GLU水平,并与镜检法检测的红细胞和白细胞、全自动生化分析仪定量检测的GLU水平进行比较。结果 :在检测尿液中红细胞和LEU时,联合应用尿液分析仪和镜检法可提高检出准确性。在检测尿液中GLU时,尿液分析仪与全自动生化分析仪的符合率较高。结论 :尿液分析仪检测红细胞和LEU时需与镜检法联合应用才能确保结果的准确性,在检测GLU时与全自动生化分析仪符合性较好,能满足临床筛查需要。
Objective To investigate the effect of GEB-600 (Gao Erbao) urine analyzer in detecting red blood cells, leukocyte esterase (LEU) and glucose(GLU) in urine. Methods:The sample of fresh urine was collected from 680 clinical outpatients. The urine analyzer was used to examine the red blood cells, LEU and GLU in urine. The levels of red blood cells and LEU were compared with those detected by microscopic examination. The GLU levele was compared with that detected by automatic biochemical analyzer. Results:The detective rates of red blood cells and LEU were improved when urine analyzer was combined with microscopy method. The high coincidence rate was seen between urine analyzer and microscopy method in detecting LEU. Conclusion:The combination of urine analyzer with microscopy method in detecting the red blood cells and LEU can ensure the accuracy of the results. It can meet the needs of the clinical screening since the result of GLU examination using urine analyzer is coincidence with automatic biochemical analyzer.
出处
《上海医药》
CAS
2014年第22期29-31,共3页
Shanghai Medical & Pharmaceutical Journal
关键词
尿液检测
尿液分析仪
诊断
urine examination
urine analyzer
diagnosis