OCT无创检测技术的人体血糖平衡延迟时间研究 被引量:5

Study on blood glucose lag time in noninvasive measurement using optical coherence tomography
下载PDF
导出
摘要 为了研究在人体血糖快速变化情况下,皮肤组织液糖浓度与血液(指血、静脉血)中血糖变化的延迟关系,采用光学相干层析技术,通过人体口服葡萄糖耐量测试和血糖钳夹实验,测量了随血糖变化的皮肤光衰减系数,并对人体血糖平衡延迟时间问题做了研究。为了避免由于延迟因素造成预测血糖值误差过大,选择700μm^800μm以下皮肤深度的真皮网状层作为分析计算区域。结果表明,延迟时间一般随着皮肤区域深度的增加而缩短;在不同的皮肤深度区域,血糖平衡延迟时间存在一定的差异性。此研究有助于提高光学无创血糖检测的准确性和可靠性。 To investigate the lag of glucose concentration between interstitial fluid of human skin and blood (peripheral blood and venous blood) during rapid change of blood glucose, optical coherence tomography (OCT) was used to measure attenuation coefficient of human skin with the change of blood glucose in oral glucose tolerance test and glucose clamp in vivo. To reduce error in prediction result, the correlation region used to calculate predicted glucose concentration should be selected below 700μm - 800μm in dermis layer. The results show that lag time decreases with the increases of depth of human skin. It is demonstrated experimentally that the lag time changes at different depths in human skin. The study can improve the accuracy and reliability of measurement value in noninvasive blood glucose sensing.
出处 《激光技术》 CAS CSCD 北大核心 2015年第1期19-22,共4页 Laser Technology
基金 国家九七三重点基础研究发展计划资助项目(2010CB327806) 国际科技合作专项基金资助项目(2010DFB13180) 江苏省基础研究计划资助项目(BK20130374) 苏州市医疗器械与新医药科技计划资助项目(ZXY2012026)
关键词 医用光学 光学相干层析 无创血糖检测 血糖平衡延迟时间 medical optics optical coherence tomography noninvasive blood glucose measurement blood glucose
  • 相关文献

参考文献11

  • 1李庆波,刘杰强,李响.基于近红外光谱技术的人体血糖浓度无创检测系统的研制[J].光谱学与光谱分析,2012,32(3):642-646. 被引量:6
  • 2李响,张广军,李庆波.一种血糖红外无创检测的改进小波预处理方法[J].光学学报,2010,30(2):579-584. 被引量:5
  • 3ENEJDER A M, SCECINA T G, OH J, et al. Raman spectroscopy for noninvasive glucose measurements [J]. Journal of Biome-dical Optics, 2005, 10(3): 031114.
  • 4ANSARI R R, BCLDE S, ROVATI L. New optical scheme for a polarimetric-based glucose sensor [J]. Journal of Biomedical Optics, 2004, 9(1): 103-115.
  • 5PLEITEZ M A, LIEBLEIN T, BAUER A, et al. In vivo noninvasive monitoring of glucose concentration in human epidermis by mid-infrared pulsed photoacoustic spectroscopy [J]. Analytical Chemistry, 2013, 85(2): 1013-1020.
  • 6KINNUNEN M, MYLLYL R, JOKELA T, et al. In vitro studies toward noninvasive glucose monitoring with optical coherence tomography [J]. Applied Optics, 2006, 45(10):2251-2260.
  • 7KURANOV R V, SAPOZHNIKOVA V V, PROUGH D S, et al. In vivo study of glucose-induced changes in skin properties assessed with optical coherence tomography [J]. Physics in Medicine and Biology, 2006, 51(16): 3885-3900.
  • 8KOSCHINSKY T, HEINEMANN L. Sensors for glucose monitoring: technical and clinical aspects [J]. Diabetes/Metabolism Research and Reviews, 2001, 17(2): 113-123.
  • 9HORI Y, YASUNO Y. Automatic characterization and segmentation of human skin using three-dimensional optical coherence tomography [J]. Optics Express, 2006, 14(5): 1862-1877.
  • 10BHANDARI A, HAMRE B, FRETTE O, et al. Modeling optical properties of human skin using Mie theory for particles with different size distributions and refractive indices [J]. Optics Express,2011, 19(15): 14549-14567.

二级参考文献29

  • 1李庆波,张鲁,汪日燕,胡小唐,徐可欣.葡萄糖水溶液浓度的近红外光谱测量法——人体血糖浓度无创伤测量方法基础研究[J].中国生物医学工程学报,2004,23(6):602-606. 被引量:10
  • 2赵莹,张元福,杨丽敏,徐怡庄,翁诗甫,杨展澜,武惠忠,周维金,徐端夫,吴瑾光.中红外光谱无创伤检测血糖新方法[J].高等学校化学学报,2005,26(6):1052-1054. 被引量:7
  • 3徐怡庄,赵莹,徐智,任予,刘毓海,张元福,周孝思,石景森,徐端夫,吴瑾光.肿瘤临床诊断的红外光谱新方法[J].光谱学与光谱分析,2005,25(11):1775-1778. 被引量:18
  • 4崔厚欣,徐可欣,陈民森,安林.人体血糖浓度近红外光谱无创检测过程中温度对结果的影响[J].光谱学与光谱分析,2006,26(5):838-841. 被引量:7
  • 5SUN Yan-kui(孙延奎).Wavelet Analysis and Application(小波分析及应用).Beijing:China Machine Press(北京:机械工业出版社),2005.233.
  • 6S. Tomas, C. Richard. Prevention of diabetes with rosiglitazone: Evidence of benefit or unexpected harm[J]. Medical Hypotheses, 2008, 70(1) : 199-200.
  • 7S. Bruce, J. Thomas, J. S. Linda et al.. Variation in antidiabetic medication intensity among medicare beneficiaries with diabetes mellitus [J]. The American Journal of Geriatric Pharmacotherapy, 2007, 5(3) : 195-208.
  • 8Jeongah Yoon, Byungwoo Lee, Chonghun Han. Calibration transfer of near-infrared spectra based on compression of wavelet coefficients [J]. Cheraometrics and Intelligent Laboratory Systems, 2002, 64(1) : 1-14.
  • 9Gang Niu, Achmad Widodo, Jong-Duk Son et al.. Decision-level fusion based on wavelet decomposition for induction motor fault diagnosis using transient current signal[J]. Expert Systems with Applications, 2008, 35(3) : 918-928.
  • 10Kunpeng Zhu, Yoke Sanwong, Geok Soonhong. Wavelet analysis of sensor signals for tool condition monitoring: A review and some new results[J]. International J. Machine Tools Manufacture, 2009, 49:537-553.

共引文献9

同被引文献39

引证文献5

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部