期刊文献+

比较测量中标准量块与被测量块材质不同时引起的误差分析 被引量:2

Analysis of measurement error caused by different material's standard gauge block and measured gauge block with comparative measurement
下载PDF
导出
摘要 通过对目前使用量块的不同材质特性说明,建立了用比较测量法测量量块的中心长度时标准量块与被测量块材质不同的测量模型,分析了在测量时温度和弹性形变产生的影响及等温处理的意义,给出引起的测量结果修正方法,并通过两个比较实例详细说明,供有关技术人员参考。 This paper through explain the material character of usinggauge block at present, build the measurement model of measuringgauge block′s center length in comparative measurement method whenthe standard gauge and measured block's material are different,analyzethe effects of temperature and the elastic deformation at the time ofmeasurement and the significance of the isothermal treatment in detail,offer the modified method of measurement result,and explain throughthe two comparative examples in detail,providing reference for thetechnicians.
作者 朱纬
出处 《上海计量测试》 2014年第6期13-14,17,共3页 Shanghai Measurement and Testing
关键词 量块 比较测量 修正值 gauge block comparative measurement modified value
  • 相关文献

参考文献4

二级参考文献1

共引文献4

同被引文献7

引证文献2

二级引证文献1