期刊文献+

POAG手术治疗进展 被引量:4

Progress in surgical treatment for primary open-angle glaucoma
原文传递
导出
摘要 POAG在药物或激光控制眼压无效时常需手术治疗.目前小梁切除术是治疗POAG最主要的手术方法,但其术中、术后并发症较常见,如前房出血、术后浅前房、滤过道纤维化等.随着手术技术的不断改进,许多治疗POAG的新方法逐渐涌现.Ex-PRESS植入术以其手术切口小、术后并发症少以及无需组织切除等特点已逐渐被广泛应用.此外,SOLX黄金分流器、人工纳米引流植入物、iStent小梁微旁路系统、Eyepass双向青光眼植入物、Aquaflow青光眼植入物、Schlemm's管成形术、小梁消融术等也分别从不同角度用于POAG的治疗. Surgical treatment tends to be the best choice for primary open-angle glaucoma (POAG) patients after medication or laser therapy fails to control intraocular pressure effectively.Trabeculectomy is currently the leading surgery for POAG even though it has complications such as hyphema,hypotony,and bleb scarring,which are commonly observed during or after operations.With the gradual improvement in surgical techniques,some new surgeries for POAG have been introduced recently.The Ex-PRESS glaucoma filtration device has been developed successfully and is in widespread use for decreasing intraocular pressure.This device is unique because it features small incision surgery and fewer complications as well as no tissue removal.Moreover,the gold micro shunt implant,artificial nano drainage implant,Glaukos iStent trabecular micro-bypass,Eyepass glaucoma implant,AquaFlow collagen implant,canaloplasty and trabectome are often performed in different aspects of POAG treatments.All of these new surgical methods are reviewed in detail.
出处 《中华眼视光学与视觉科学杂志》 CAS 2014年第10期631-635,共5页 Chinese Journal Of Optometry Ophthalmology And Visual Science
关键词 原发性开角型青光眼 Ex-PRESS青光眼引流装置 Schlemm's管成形术 小梁消融术 Primary open-angle glaucoma (POAG) Ex-PRESS glaucoma filtration device Canaloplasty Trabectome
  • 相关文献

参考文献43

  • 1Caprioli J, Coleman AL. Intraocular pressure fluctuation a risk factor for visual field progression at low intraocular pressures in the advanced glaucoma intervention study[J]. Ophthalmology, 2008,115 : 1123-1129.
  • 2Sihota R. Lasers in primary open angle glaucoma[J]. Indian J Ophthalmol, 2011,59 : S 114-S 117.
  • 3Baumgartner JM, Ngondi CE, Bovet J, et al. Filtering surgery in glaucoma: comparative study of three surgical approaches[J]. J Fr Ophtalmol,2012,35:705-715.
  • 4Nyska A, Glovinsky Y, Belkin M, et al. Biocompatibility of the Ex-PRESS miniature glaucoma drainage implant[J]. J Glaucoma, 2003,12 : 275-280.
  • 5De Feo F, Jacobson S, Nyska A, et al. Histological biocompatibility of a stainless steel miniature glaucoma drainage device in humans: a case report[J]. Toxicol Pathol, 2009,37:512-516.
  • 6Aziz H, Fantes F, Dubovy S. Histopathology of the Ex-PRESS shunt[J]. Ophthalmic Surg Lasers Imaging,2011,42:e94-e96.
  • 7Gandolfi S, Traverso CF, Bron A, et al. Short-term results of a miniature drainage implant for glaucoma in combined surgery with phacoemulsification[J]. Acta Ophthalmol Scand (Suppl), 2002,236 : 66.
  • 8Traverso CE, De Feo F, Messas-Kaplan A, et al. Long-term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surger with Phacoemulsification[J]. Br J Ophthalmol, 2005,89:425-429.
  • 9Wamsley S, Moster MR, Rai S, et ah Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study[J]. Am J Ophthalmol,2004,138 : 1049-1051.
  • 10Rivier D, Roy S, Mermoud A. Ex-PRESS R-50 miniature glaucoma implant insertion under the conjunctiva combined with cataract extraction[J]. J Cataract Refract Surg,2007,33: 1946-1952.

同被引文献44

  • 1丁体英,余杰.非穿透小梁手术联合羊膜移植治疗继发开角型青光眼的护理[J].护理学杂志(外科版),2005,20(5):35-36. 被引量:4
  • 2王峥嵘,罗汉萍.个体化健康教育对青光眼病人用药依从性的影响[J].护理研究(下旬版),2007,21(2):525-527. 被引量:24
  • 3TOJO N, HAYASHI A, MIYAKOSH1 A. Corneal decompensation following filtering surgery with the Ex-PRESS mini glaucoma shunt device [ J]. Clin Ophthalmol,2015,17 ( 9 ) :499-502.
  • 4MARIOTTI C, DAHAN E, NICOLAI M, LEVITZ L, BOUEE S. Long-term outcomes and risk factors for failure with the EX- press glaucoma drainage device [J]. Eye ( Lond ), 2014,28 (8) :1034-1035.
  • 5FUKUDA S, BEHEREGARAY S, KASARAGOD D, HOSHI S, KISHINO G, ISHII K. Noninvasive evaluation of phase retarda- tion in blebs after glaucoma surgery using anterior segment polarization-sensitive optical coherence tomography[J]. In- vest Ophthalmol Vis Sci ,2014,55 ( 8 ) :5200-5206.
  • 6VILAMARIN A, STERGIOPULOS N, BIGLER S. tn vivo tes- ting of a novel adjustable glaucoma drainage device[J]. In- vest Ophthalmol Vis Sci ,2014,55 ( 11 ) :7520-7524.
  • 7MABRAY MC, UZELAC A, TALBOTT JF, LIN SC, GEAN AD.Ex-PRESS glaucoma filter: an MRI compatible metallic or- bital foreign body imaged at I. 5 and 3T[ J]. Clin Radiol, 2015,70(5) :28-34.
  • 8Dai ZX,Yu XB,Hong JX,et al.Development of a novel Cs APLGA drug delivery system based on a glaucoma drainage device for the prevention of postoperative fibrosis[C].Mate Sci&Amp;Engineering C,2016.
  • 9Jung Kyoung In,Park Chan Kee.Pirfenidone inhibits fibrosis in foreign body reaction after glaucoma drainage device implantation[J].Drug Des Devel Ther,2016,10(6):125-130.
  • 10Lars Choritz,Jochen Grub,Maria Wegner,Norbert Pfeiffer,Hagen Thieme.Paclitaxel inhibits growth,migration and collagen production of human Tenon's fibroblasts-potential use in drug-eluting glaucoma drainage devices[J].Graefe's Archive for Clinical and Experimental Ophthalmology,2010,2482.

引证文献4

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部