Temperature and Concentration Fields in a Generator Integrated to Single Stage Heat Transformer Using Water/Carrol Mixture
Temperature and Concentration Fields in a Generator Integrated to Single Stage Heat Transformer Using Water/Carrol Mixture
摘要
The generator is the starter device of single stage heat transformer(SSHT) and its characteristics have main effects on the overall efficiency of this kind of absorption machines.This article reports a study of the generation of steam and changes in the concentration of the working solution(Water/Carrol mixture) into a plate heat exchanger as a function of its horizontal and vertical position by gravity effect.It is considered the analysis of six experimental tests;two were evaluated in a plate heat exchanger in a horizontal position and four in a vertical position(90 degree inclination).The generation of steam and increased concentration of the working solution are more sensitive to the vertical position of exchanger than in horizontal position.The results of numerical-experimental analysis indicates that a heat exchanger in horizontal position,the steam generation and the change in the concentration of the working solution occurring in the middle of the plate(or at greater distance depending to the thermodynamic conditions) and instantly in vertical position(at the input of the plate).
基金
supporting basic science project 167434:"Analysis of waste energy recovery and sustainable development"
二级参考文献8
-
1Yang S M, Tao W Q. Heat Transfer. 4th ed. Beijing: Higher Education Press, 2008. (in Chinese).
-
2Kakac S, Shah R K, Aung W. Handbook of Single-phase Convective Heat Transfer. New York: John Wiley, 1987.
-
3Kays W M, Crawford M E. Convective Heat and Mass Transfer. 4th ed. New York: McGraw-Hill Inc, 2007.
-
4Sellars J R, Tribus M, Klein J S. Heat transfer to laminar flow in round tubes or flat conduit-The Graetz Problem extended. Tran ASME, 1956, V(78): 441-448.
-
5Cess R D, Shaffer E C, Heat Transfer to Laminar Flow Between Parallel Plates with a Prescribed Wall Heat Flux, Appl. Sci. Res., Vol. A8, pp. 339-344, 1959.
-
6Prins J A, Mulder J, Schenk J. Heat transfer in laminary flow between parallel plates. Appl. Sci. Res. A2(1951 ) 431.
-
7Yuan Z X, Zhang J G, Jiang M J. Analytical study on co- ordinative optimization of convection in tubes with vari- able heat flux. Science in China Series E: Technological Sciences, Volume 47, Number 6, 651-658, (in Chinese).
-
8Shah R K, London A L. Thermal boundary conditions and some solutions for laminar duct flow forced convec- tion. Journal of Heat Transfer, Trans. ASME, series C, Vol(96), 1974, pp. 159-165.
-
1翟正刚.耕地作业中常见故障的排除[J].农家科技,2007(1):48-48.
-
2刘恩栋,罗春.空气监测站布点准则的研究[J].武汉交通科技大学学报,1998,22(4):400-402. 被引量:1
-
3林雨.耕地作业常见故障及排除方法[J].致富天地,2008(12):38-38.
-
4徐树来,孔令波,辛萍,肖干生.割前脱粒中梳脱滚筒和螺旋搅龙位置关系的试验研究[J].黑龙江八一农垦大学学报,2001,13(1):46-49.
-
5提供全方位服务的Valtimet公司[J].不锈,2010(2):49-50.
-
6安全在我心中[J].小樱桃(好少年),2012(12):14-15.
-
7张树明.机械手表保养法[J].农村新技术,1994,0(5):52-52.
-
8程建峰,潘晓云,方加海,刘宜柏.旱作条件下水陆稻灌浆期根系生长特性研究[J].江西农业大学学报,1999,21(2):149-152. 被引量:4
-
9Gilmore,F.William.水净化用电絮凝反应室[J].水处理信息报导,2007(3):42-42.
-
10Ehab M. Attalla.Comparison of two methods for assessing leakage radiation dose around the head of the medical linear accelerators[J].The Chinese-German Journal of Clinical Oncology,2013,12(9):435-438. 被引量:1