摘要 目的:研究制定战储多参数监护仪质量控制方法,进一步提升战储多参数监护仪储备质量。方法:结合战储多参数监护仪的维护保养技术要求,对入库验收、登记统计、环境控制、维护保养、出库检验等各个环节进行分析研究。结果:建立了基于不同储存环节的战储多参数监护仪质量控制方法,成功应用于战储卫生装备维护保养工作实践。结论:不断研究完善战储卫生装备质量控制方法,可有效提升装备完好率和应急保障能力。 Objective To study the quality control method for combat readiness multi-parameter monitor to enhance its quality during storage. Methods The requirements of the monitor were taken into considerations, and all links were analyzed for warehouse-in acceptance, register and statistics, environmental control, maintenance, warehouse-out detection and etc. Results The quality control method for combat readiness multi-parameter monitor was established for different links, and was applied practically. Conclusion The quality control method for combat readiness multi-parameter monitor contributes to the equipment fitness and ability of emergent support.
出处 《医疗卫生装备》 CAS 2014年第11期30-32,共3页 Chinese Medical Equipment Journal
基金 军事医学计量科研专项课题(2012-JL1-008)
关键词 战储 多参数监护仪 质量控制 combat readiness multi-parameter monitor quality control
  • 相关文献

参考文献6

二级参考文献21

  • 1耿雪霏.RFID技术在物流管理中的应用[J].包装工程,2005,26(2):118-119. 被引量:26
  • 2廉小亲,翁贻方.基于电子标签的仓储物流控制及管理系统[J].计算机工程与设计,2007,28(10):2426-2428. 被引量:12
  • 3郭勇.医学计量[M].北京:中国计量出版社,2002.7-12.
  • 4张玉明 李毅 孙志辉 等.强检类部队卫生装备计量管理方法研究.医疗卫生装备,2007,28(4):128-129.
  • 5龙雨 李芳.RFID安全方案研究.计算机工程应用技术,2008,4(7):1887-1888.
  • 6GJB 5109—2004装备计量保障通用要求——检测和校准[S].
  • 7GJB 5338—2005卫生装备质量分级和转级、退役与报废通用技术条件[S].
  • 8GJB5338-2005 卫生装备质量分级和转级、退役与报废通用技术条件[S].
  • 9GJB 5109—2004装备计量保障通用要求:检测和校准[S].
  • 10陈晓红,任国荃,周丹,石虹.医疗设备质量控制体系构建实践与研究[J].解放军医院管理杂志,2008,15(4):384-386. 被引量:84

共引文献19

同被引文献36

引证文献4

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部