期刊文献+

南方某铀矿井下炸药库回潮原因分析及控制措施 被引量:1

Analysis and control measure of resurgence reason of explosive storage under pit in one southern uranium deposit
下载PDF
导出
摘要 分析南方某铀矿井下炸药库回潮的原因,提出控制炸药库回潮的技术措施.通过调整炸药库通风系统,库内空气相对湿度明显降低,最高相对湿度从93.1%降至70.1%,最低相对湿度从88.4%降至57.3%,达到库房内相对湿度宜保持在50%~80%的要求,从而较好解决了炸药库的回潮问题. The reason of resurgence of explosive storage under pit in one southern uranium deposit was analyzed, and control technique of resurgence of explosive storage under the pit was put forward. By adjustment of ventilation system of explosive storage, the relative moisture of explosive storage is ap- parently decreased. The highest relative moisture is decreased to 70.1% from 93.1%, and the lowest relative moisture is decreased to 57.3% from 88.4%, the relative moisture in storage is maintained at the requirement between 50% and 80%.
出处 《铀矿冶》 CAS 2014年第4期227-230,共4页 Uranium Mining and Metallurgy
关键词 炸药库 回潮 相对湿度 explosive storage resurgence relative moisture
  • 相关文献

参考文献5

二级参考文献30

  • 1李鑫,李忠,韦利飞,肖静,肖利民.除湿材料研究进展[J].化工进展,2004,23(8):811-815. 被引量:35
  • 2方利国,谭盈科.除湿制冷系统及除湿器研究进展[J].广东化工,1995,22(3):15-19. 被引量:9
  • 3电子工业部第十设计研究院.空气调节设计手册[M].2版.北京:中国建筑工业出版社,2000:443-460
  • 4Vian J G,Astrain D,Dominguez M.Numerical modeling and a design of a thermoelectric dehumidifier[J].Applied Thermal Engineering,2002,22(4):407-422
  • 5Tashtoush B,Molhim M,Al-Rousan M.Dynamic model of an HVAC system for control analysis[J].Energy,2005,30 (10):1729-1745
  • 6Perera C O,Rahman M S.HVAC dehumidification systems for thermal comfort:a critical review[J].Trends in Food Science & Technology,1997,8(3):75-79
  • 7Iwahara H,Matsumoto H,Takeuchi K.Electrochemical dehumidification using proton conducting ceramics[J].Solid State Ionics,2000(136/137):133-138
  • 8Wang Chung Tsair,Wu Honda.Mass transfer correlation for dehumidification of air in a packed absorber with an inverse U-shaped tunnel[J].Separation Science and Technology,2000,35 (10):1503-1515
  • 9Stefano B,Anna C.Experimental and theoretical analysis of air humidification/dehumidification processes using hydrophobic capillary contactors[J].Applied Thermal Engineering,2001,21 (11):1119 -1135
  • 10Carlo I,Enrico N,Anna M.On the application of a membrane air-liquid contactor for air dehumidification[J].Energy and Buildings,1997,25(3):185-193

共引文献38

同被引文献5

  • 1朱冬生,剧霏,李鑫,汪南,刘超.除湿器研究进展[J].暖通空调,2007,37(4):35-40. 被引量:32
  • 2湖北长石矿劳安科.井下炸药库防潮[J].冶金安全,1976(5):14.
  • 3王文斌,苏正美.井下炸药库防潮方法浅析[J].冶金安全,1984(4):36-39.
  • 4王海桥,郝小礼,张书国,等.一种矿用隔爆型等温除湿机:中国,201220532356.6[P].2013-03-27.
  • 5王文斌,苏正美,刘晓初,张文礼,鲁天保,彭祖玉.井下炸药库冷冻除湿的现场试验[J].工业安全与环保,1985,26(6):5-8. 被引量:2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部