摘要 介绍了电子式阻容分压电压互感器的工作原理,重点阐述了利用补偿电抗器并联接入GIS管道对110 kV电子式电压互感器进行谐振升压.通过与传统级联变压器升压方式实验数据的对比分析,论证了并联谐振升压在带GIS管道情况下具有操作简单、一次电流小、安全可靠性高、适用性强等特点. The working principle of electronic voltage transformer based on resistive -capacitive divider is introduced, and the focus of description is that resonance boosting is carried out for 110 kV electronic voltage transformers by using compensation reactor connected in parallel with GIS pipeline. Compared with the experimental data of traditional boosting methods for cascade transformer, it is demonstrated that the parallel resonance boosting has the characteristics of simple operation, small primary current, high security and reliability and good applicability in case of GIS pipeline.
出处 《四川电力技术》 2014年第A01期44-48,共5页 Sichuan Electric Power Technology
关键词 电子式互感器 阻容分压 GIS 补偿电抗器 并联谐振 electronic voltage transformer resistive -capacitive divider GIS compensation reactor parallel resonance