期刊文献+

超声引导下及传统解剖定位下行深静脉穿刺置管术在血液净化中的比较 被引量:6

Comparison of Ultrasound Guidance and Traditional Anatomical Location Under Deep Vein Catheterization in Blood Purification
下载PDF
导出
摘要 目的探讨B超定位下与传统解剖定位下行深静脉穿刺置管术在血液净化治疗中的优劣。方法选择100例行血液净化深静脉穿刺置管患者,随机分为两组,A组(50例)在B超定位下行颈内静脉穿刺置管术;B组(50例)在传统解剖定位下行颈内静脉穿刺置管术。观察:1穿刺及钢丝置入一次性成功率。2不良事件发生率。结果 A组患者穿刺及钢丝置入一次性成功率均高于B组;损伤动脉发生率、维持性血液净化治疗过程中深静脉管路血流量不足发生率、深静脉管路感染及堵塞并发症的发生率均低于B组(P<0.05)。结论在超声引导下行深静脉穿刺置管术是一种快速准确、安全有效的方法,适用于需行血液净化治疗的患者。 Objective To investigate the effect of B-ultrasound locations and traditional anatomical locations under deep vein catheterization in blood purification treatment. Methods Choose 100 patients with Deep vein catheterization,randomly divided into two groups, group A(50 cases)in B-ultrasonic locations under jugular vein catheterization; group B(50 cases)in the traditional anatomical location under jugular vein catheterization. Observation:q)right-first-time success rate of puncture and wire placement. ~the incidence of adverse events. Result The right-first-time success rote of puncture and wire placement in group A was higher than that in group B; the incidence of Arterial injury, the incidence of deep vein pipe insufficient blood flow and deep vein pipe infection and blocking complications in the process of blood purification treatment in group A were lower than that in group B(P〈0.05). Conclusion The ultrasound-guided catheterization was a quickly and accurately, safe and effective method, which is suitable for the need of blood purification therapy patients.
出处 《中国医药指南》 2014年第32期47-48,共2页 Guide of China Medicine
关键词 B超定位 深静脉置管术 血液净化 B-ultrasound locations Deep vein catheterization Blood puriifcation
  • 相关文献

参考文献8

  • 1Bekgaard N,Klitfod L,Broholm R.Safety and efficacy of catheter- directed thrombolysis[J].Phlebology,2012,27( 1): 149-154.
  • 2Tsygankov VN,Varava AB.Antegrade catheterization of the brach- ial artery during treatment of arteriovenous angiodysplasia of the forearm and hand[J].Angiol Vasc Surg,2013,19(1):53-58.
  • 3金永红,伍彩霞,吕立友.深静脉穿刺置管术在重危患者抢救中的应用[J].河北医学,2009,15(1):90-93. 被引量:7
  • 4Oguzkurt L,Tercan F,Kara G,et al.US-guided placement of temp- orary internal jugular vein catheters: immediate technical success and complications in normal and high-risk patients[J].Eur J Radiol, 2005,55(1): 125-I29.
  • 5Chemaly RF, Parres JB,Rehm SJ.Venous thrombosis associated with peripherally inserted ceniral catheter:a retrospective analysis of the cleveland clinic experience[J].Clin Infect Dis,2002,34(9): 1179-1183.
  • 6Wilson TJ,Brown DL,Meurer WJ,et al.Risk factors associated with peripherally inserted central venous catheter-related large vein thrombosis in neurological intensive care patients[J].Intens Care Med,2012,38(2):272-278.
  • 7Akoglu H,Piskinpass S,Yenigun EC,et al.Real-time ultrasound guided placement of temporary internal jugular vein catheters: Assessment of technical success and complication rates in neph- rology practice[J].Nephrology,2012,17(7):603-606.
  • 8Justin R,Wallace,Rabih A,et al Report on the Hemodialysis Relia- ble Outflow(HeRO) experience in dialysis patients with central venous occlusions[J].J Vase Surg,2013,58(3):742-747.

二级参考文献5

共引文献6

同被引文献47

  • 1Misanovic V, Jonuzi F, Anic D, et al. Central venous cathe- ter as vascular approach for hemodialysis-our experiences [ J ]. Mater Sociomed, 2015, 27(2) : 112 - 113. DOI: 10. 5455/ msm. 2015.27. 112-113.
  • 2Wilson T J, Brown D L, Meurer W J, et al. Risk factors as- sociated with peripherally inserted central venous catheter-re- lated large vein thrombosis in neurological intensive care pa- tients [ J]. Intensive Care Med, 2012, 38 ( 2 ) : 272 - 278. DOI : 10. 1007/s00134-011-2418-7.
  • 3Sobolev M, Slovut D P, Lee-Chang A, et al. Ultrasound- Guided Catheterization of the Femoral Artery: A Systematic Review and Meta-Analysis of Randomized Controlled Trials [j]. J Invasive Cardiol, 2015, 27(7): 318 -323.
  • 4Su E, Kantor D B, Conlon T. Looking for Tips on Central Venous Catheter Insertion? Try Ultrasound [ J ]. Pediatr Crit Care Med, 2015, 16(9) : 891 -893. DOI: 10. 1097/PCC. 0000000000000517.
  • 5Yamamoto A, Suzuki K, Sakaida H, et al. Management of inadvertent vertebral artery injury due to central venous cathe- terization in a coagulopathic patient [ J ]. Acute Medicine & Surgery, 2015, 637:213-218. DOI: 10. 1002/ams2. 177.
  • 6Li Z, Chen L. Comparison of ultrasound-guided modified Seldinger technique versus blind puncture for peripherally in- serted central catheter: a meta-analysis of randomized con- trolled trialsIJ]. Crit Care, 2015, 19: 64. DOI: 10. 1186/ s13054-015-0742-y.
  • 7Scoppettuolo G, Pittiruti M, Pitoni S, et al. Ultrasound- guided "short" midline catheters for difficult venous access in the emergency department: a retrospective analysis [ J ]. Int J Emerg Med, 2016, 9(1) : 3. DOI: 10. 1186/s12245- 016-0100-0.
  • 8Ishizuka M, Nagata H, Takagi K, et al. Right internal jugu- lar vein is recommended for central venous catheterization [J]. J Invest Surg, 2010, 23(2) : 110 - 114. DOI: 10. 3109/08941930903469342.
  • 9Akoglu H, Piskinpasa S, Yenigun E C, et al. Real-time ul- trasound guided placement of temporary internal jugular vein catheters: assessment of technical success and complication rates in nephrology practice [ J ]. Nephrology ( Carlton ), 2012, 17 (7) : 603 - 606. DOI: 10. llll/j. 1440-1797. 2012. 01637. x.
  • 10王庆涛,王志力,钟挺,陈娟,黄丽萍.临床麻醉中颈内静脉与锁骨下静脉穿刺置管成功率及并发症的比较[J].现代医药卫生,2011,27(3):344-345. 被引量:1

引证文献6

二级引证文献22