髋关节假体聚乙烯磨损及其影响因素的相关性分析 被引量:2

Correlations between polyethylene wear direction and other influencing factors in total hip arthroplasty
原文传递
导出
摘要 目的 探讨磨损与假体植入参数的相关性.方法 1997年4月至2006年3月对南方医科大学附属南方医院关节与骨病外科58髋Zweymuller双锥面非骨水泥螺旋臼假体进行临床和影像学检查,以计算机辅助测量方法测量髋关节假体聚乙烯内衬的线性磨损,平均随访时间为7.3年.利用股骨头假体中心相对于髋臼杯开口平面轴线的矢量位移,来决定线性磨损的大小和方向.分析髋臼外展角、股骨偏心距、髋臼前倾角对线性磨损方向和大小的影响.结果 平均线性磨损率为(0.17±0.08) mm/年,平均线性磨损方向与髋臼杯轴线的夹角为(34.2±29.3)°.线性磨损方向与外展角存在正相关性(r=0.480,P=0.000),与术后Harris评分存在负相关性(r=-0.314,P=0.016).外展角>45°组的线性磨损方向较外展角< 45°组更加偏离髋臼轴心(P=0.001).术中股骨偏心距得到重建组的线性磨损率小于未得到重建组(P =0.043).结论 该计算机辅助测量方法适用于各种髋臼杯假体聚乙烯内衬的二维磨损测量.人工全髋关节置换术中合理的髋臼杯外展角和恢复正常偏心距可以减少聚乙烯内衬线性磨损率,增加髋关节假体的稳定性,改善远期效果. Objective To explore the correlations between polyethylene wear direction and implanted parameters of prosthesis in total hip arthroplasty (THA) by computer-assisted measurement techniques.Methods Retrospective analyses were performed for 58 uncemented THAs from April 1997 to March 2006.The sagittal displacement of femoral head to axis of acetabulum opening plane was examined to determine the direction and degree of linear polyethylene wear.Radiographs were assessed for femoral offset,acetabular abduction,acetabular anteversion and conventional polyethylene wear.The linear polyethylene wear directions were compared between different parameter groups.Results The average linear wear rate was 0.17 ± 0.08 mm/year and the angle between linear wear direction and axis of acetabulum 34.2° (± 29.3 °).Linear wear direction and acetabular abduction were positively relevant (r =0.480,P =0.000).Linear wear direction was negatively correlated with postoperative Harris scores (r =-0.314,P =0.016).Compared with the acetabular abduction of < 45°,the acetabular abduction of 45° or larger was associated with greater decentralization of acetabulum opening plane (P =0.001).As an independent variable,there were no statistically significant difference in linear wear direction between different acetabular anteversions.And femoral offset had no significant association with linear wear direction (P > 0.05).Conclusion Reasonable acetabular abduction and femoral offset may decrease linear wear rates,maintain hip stability and improve long-term putcomes.
出处 《中华医学杂志》 CAS CSCD 北大核心 2014年第43期3416-3420,共5页 National Medical Journal of China
关键词 关节成形术 置换 聚乙烯 放射测量术 髋臼 Arthroplasty, replacement, hip Polyethylene Radiometry Acetabulum
  • 相关文献

参考文献18

  • 1Holt G, Murnaghan C, Reilly J, et al. The biology of aseptic osteolysis. [ J]. Clin Orthop Relat Res,2007,460:240-252.
  • 2戴闽,程明,刘虎诚,程细高,范红先,张斌.不同浓度金属磨损颗粒对破骨细胞体外分化的影响[J].中国矫形外科杂志,2011,19(4):316-319. 被引量:11
  • 3Widmer KH. A simplified method to determine aeetabular cup anteversion from plain radiographs [ J ]. J Arthroplasty, 2004,19 : 387-390.
  • 4Zweymuller KA, Steindl M, Schwarzinger U. Good stability and minimal osteolysis with a biconical threaded cup at 10 years [ J ]. Clin Orthop Relat Res,2007,463 : 128-137.
  • 5兰天,肖军,史占军.人工全髋关节假体聚乙烯磨损的测量[J].中华医学杂志,2012,92(9):645-648. 被引量:3
  • 6Pospischill M, Knahr K. Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years[J]. J Bone Joint Surg Br,2005 ,87 :1210-1215.
  • 7Vervest TM, Anderson PG, Van Hout F, et al. Ten to twelve-year results with the Zweymuller cementless total hip prosthesis [ J ]. J Arthroplasty, 2005,20 : 362 -368.
  • 8Christodoulou NA, Dialetis KP, Christodoulou AN. High hip center technique using a biconical threaded Zweymuller cup in osteoarthritis secondary to congenital hip disease[J]. Clin Orthop Relat Res ,2010 ,468 : 1912-1919.
  • 9D'Lima DD, Urquhart AG, Buehler KO, et al. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. [ J ]. J BoneJoint Surg Am,2000,82:315-321.
  • 10Little N, Busch C, Gallagher J, et al. Acetabular polyethylene wear and acetabular inclination and femoral offset[ J]. Clin Orthop Relat Res ,2009,467:2895-2900.

二级参考文献56

  • 1程涛,戴闽,范红先,刘虎诚,郝亮,程细高.氧化铝陶瓷和高分子聚乙烯颗粒诱导体内生物学效应和细胞凋亡的研究[J].中华实验外科杂志,2007,24(1):113-113. 被引量:14
  • 2Cobb AG, Schmalzreid TP. The clinical significance of metalion release from cobalt-chromium metal-on-metal hip joint arthro plasty [ J ]. Proclnst Mech Eng,2006 ,2 :385 - 398.
  • 3Battaglino R, Kim D, Fu J, et al. C-mye is required for osteoclast differentiation[ J]. J Bone Miner Res,2002,5:763 - 773.
  • 4Hsu H, Lacey D, Dunstan C,et al. Tumor necrosis factor receptor family member RANK mediates osteoclast differentiation and activation inducedby osteoprotegerin ligand[ J]. Proc Natl Acad Sci USA, 1999,7: 3540 - 3545.
  • 5Yamamoto A, Miyazaki T, Kadono Y, et al. Possible involvement of IkappaB kinase 2 and MKK7 in osteoclastogenesis induced by receptor activator of nuclear factor kappaB ligand [ J ]. J Bone Miner Res, 2002,4:612 - 621.
  • 6Mizukami J, Takaesu G, Akatsuka H, et al. Receptor activator of NfkappaB ligand (RANKL) activates TAK1 mitogen-aetivated protein kinase kinase through a signaling complex containing RANK, TAB2, and TRAF6 [ J ]. Mol Cell Biol, 2002,4 : 992 - 1000.
  • 7Shadduek RK, Waheed A, Mangan KF, et al. Preparation of a monoclonal antibody directed against the receptor for murine colony-stimulating factor - 1 [ J ]. Exp Hematol, 1993,4:515 - 520.
  • 8Koscki T ,Gao Y ,Okahashi N ,et al. Role of TGF - beta family in osteoclastogenesis induced by RANKL[ J]. Cell Signal ,2002,1 : 31 - 36.
  • 9Suda T, Udagawa N, Nakamura I, et al. Modulation of ostcoclast differentiation by local factors [ J ]. Bone, 1995,2 : 87 - 91.
  • 10Theoleyre S, Wittrant Y, Tat SK, et al. The molecular triad OPG/ RANK/RANKL: involvement in the orchestration of pathophysiological bone remodeling [ J ]. Cytokine Growth Factor Rev,2004,6: 457 - 475.

共引文献44

同被引文献10

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部