摘要
目的探讨课题组构建的一种新型仿生人工神经导管修复人周围神经缺损的临床疗效。方法对2011年12月至2012年12月期间的上肢周围神经缺损病例使用该神经导管进行手术修复并进行随访,以"中华医学会手外科学会上肢部分功能评定试用标准"对相应的神经功能进行评估。结果共计8例病例均获得随访,6例神经功能有一定改善,其中优2,良3例,可1例。结论该神经导管修复周围神经缺损具有良好的效果,为一种较为理想的周围神经缺损的修复材料。
Objective To explore the clinical effect of a novel bionic artificial nerve conduit on repairing defect of peripheral nerves. Methods From December, 2011 to December, 2012, patients suffered from peripheral nerve defect of upper limbs were treated by surgical treatments using the artificial nerve conduits and followed up. "The Upper Extremity Functional Evaluation Standard by Hand Surgery Branch Of Chinese Medical Association" was used to evaluate the neural function. ResuRs A total of 8 cases received following-up. Neural function of 6 cases was partially restored among which 2 cases got excellent result, 3 cases good and 1 cases fair. Conclusion This novel nerve conduit showed good effect on defect of peripheral nerve and consequently was an ideal repairing materials for peripheral nerve defect.
出处
《中国临床解剖学杂志》
CSCD
北大核心
2014年第6期735-738,共4页
Chinese Journal of Clinical Anatomy
关键词
神经导管
周围神经
临床研究
神经缺损
Nerve conduit
Peripheral nerve
Clinical research
Nerve defect