期刊文献+

循环加载对不同涂布次数下粘结剂粘结强度的影响 被引量:1

Effect of Cycling Mechanical Loading on the Bond Strength with Different Coating Times
下载PDF
导出
摘要 目的:观察在离体牙上循环加载对不同涂布次数下第七代粘结剂Easy One粘结强度的影响。方法:选择90个离体前磨牙制备标准I类洞型后,随机分3组,涂布1次(A组)、涂布2次(B组)、涂布3次(C组),根据相应涂布次数处理后进行树脂充填。每组又随机分3组,无加载组(a组)、加载10000次组(b组)、加载60000次组(c组)。各组在加载后经薄片推出试验测定各组的粘结强度值。结果:各组的粘结强度值为:Aa(33.91±4.17)MPa,Ab(30.93±4.47)MPa,Ac(22.82±4.68)MPa,Ba(35.73±4.35)MPa,Bb(32.40±4.43)MPa,Bc(24.13±4.59)MPa,Ca(28.15±4.30)MPa,Cb(24.85±4.70)MPa,Cc(16.61±4.66)MPa,相同的涂布次数条件下,加载60000次组界面的粘结强度明显小于加载10000次组或无加载组(P<0.05);相同的加载次数条件下,涂布3次的粘结界面强度小于涂布2次和涂布1次的粘结界面强度,差异具有统计学意义(P<0.05)。结论:循环加载会使牙本质粘结剂的粘结强度下降;不同涂布次数中,涂布1次、2次的均能得到较为理想的粘结强度。 Objective: To study the effect of cycling mechanical loading on the bond strength of the 7th dentin adhesion agent with different coating times. Methods: 90 fresh premolars that was extracted for Orthodontic reasons were selected prepared by the standard of Class - 1 hole type, and divided into 3 groups according to the coating times (A coating 1 time, B coating 2 times, C coating 3 times). Then they were filled with resin restoration. Each group was randomly divided into 3 groups again, which is, one experimental group of a, cycling-loading 10000 times, one experimental group of b , cycling-loading 60000 times, one control group of c , non- cycling-loading. Then we determined the bond strength of each sample. Results: The bond strength of each group is Aa(33. 91±4. 17)MPa, Ab(30. 93±4. 47)MPa, Ac(22. 82±4. 68)MPa, Ba(35. 73±4. 35)MPa, Bb(32. 40±4. 43)MPa, Bc(24. 13±4. 59)MPa, Ca(28.15±4. 30)MPa, Cb(24. 85±4. 70)MPa, Cc(16. 61±4. 66)MPa; The bond strength in the group of cycling - loading 60000 times is obviously less than the group of cycling - loading 10000 times and the group of non - cycling-loading with coating same time (P〈0. 05); the bond strength of the group coating 3 times is obviously decreased (P〈0. 05). Conclusion: The bond strength of dentin adhesionagent reduces with the increase of cycling mechanical loading times. Better bond strength could be gained when coating 1 time or 2 times.
出处 《口腔医学研究》 CAS CSCD 2014年第11期1037-1040,共4页 Journal of Oral Science Research
基金 2011~2013年卫生部公益基金课题(编号:201002017)
关键词 循环加载 粘结强度 粘结剂 涂布方式 Cycling mechanical loading Bond strength Adhesion agent Coating types
  • 相关文献

参考文献10

  • 1郑铁丽,黄翠,张智星,王飒,张帼.离体牙储存方式对牙本质黏结剂微拉伸强度的影响[J].上海口腔医学,2005,14(2):147-150. 被引量:20
  • 2Delong R, Douglas, WH. Development of an artificial oral environment for the testing of dental restoratives: bi- axial force and movement control [J]. J Dent Res, 1983, 62(1) : 32-36.
  • 3亓莉莉,聂二民,陈霞云,刘克瑾,黄颖荷,刘伟,张春元.口腔修复体疲劳抗性测试机的研制[J].广东牙病防治,2009,17(12):582-585. 被引量:2
  • 4林宝山,姜婷,孔宁华.冷热循环机械载荷咀嚼模拟疲劳试验机的研制及标定[J].北京口腔医学,2006,14(2):132-134. 被引量:13
  • 5Gordan VV, Mjor IA. Short- and long-term clinical evalu ation of post-operative sensitivity of a new resin-based re storative material and self-etching primer [J]. Oper Dent 2002, 27(6) : 543-548.
  • 6Arisu HD,EligiJzeloglu E,Uctasli MB, et al. Effect of multi- ple consecutive applications of one-step self-etch adhesive on micro-tensile bond strength [J]. J Contemp Dent Pract, 2009, 10(2) : 67-74.
  • 7Balbosh A, Kern M. Effect of surface treatment on retention of glass-fiber endodontic posts [J]. J Prosthet Dent, 2006, 95(4) : 218-223.
  • 8Schreiner RF, Chappell RP, Claros AG, et al. Microtensile testing of dentin adhesive [J]. Dent Mater , 1998, 14(6) : 194-201.
  • 9Goracci C, Sadek FT, Fabianelli A,et al. Evaluation of the adhesion of fiber posts to intraradicular dentin [J]. Oper Dent, 2005, 30(5) : 627-635.
  • 10Darbyshire PA, Messer LB, Douglas WH. Microleakage in class II composite restorations bonded to dentin using thermal and lord cycling[J]. J Dent Res, 1988, 67(3) : 585-587.

二级参考文献29

  • 1姜涛,王景云,徐经伟,孙宏晨,孙伟.UB-I粘结剂粘结面的微形态观察[J].口腔医学研究,2004,20(3):277-279. 被引量:1
  • 2Goto Y, Nicholls JI, Phillips KM, et al. Fatigue resistance of end- odontically treated teeth restored with three dowel-and-core systems. J Prosthet Dent, 2005,93 ( 1 ) :45-50.
  • 3Ottl P, Hahn L, Lauer HCh, et al. Fracture characteristics of carbon fibre, ceramic and non-palladium endodontie post systems at monotonously increasing loads. J Oral Rehabil. 2002,29 (2) : 175-183.
  • 4Sahafi A, Peutzfcldt A, Ravnholt G, et al. Resistance to cyclic loading of teeth restored with posts. Clin Oral Investig, 2005,9(2) :84- 90.
  • 5Baldissara P, Di Grazia V, Palano A, et al. Fatigue resistance of restored endodontically treated teeth: a multiparametric analysis, lnt J Prosthodont, 2006,19 ( 1 ) :25-27.
  • 6Mannocci F, Ferrari M, Watson TF. Microleakage of endodontically treated teeth restored with fiber posts and composite cores after cyclic loading: a confoeal microscopic study. J Prosthet Dent, 2001,85 (3) :284-291.
  • 7Tay FR, Pashley DH. Dental adhesives of the future [J]. J Adhes Dent,2002,4(2):91-103.
  • 8Dewald JP. The use of extracted teeth for in vitro bonding studies:a review of infection control considerations [J]. Dent Mater, 1997,13(2):74-81.
  • 9Toledano M, Osorio R, Ceballos L, et al. Microtensile bond strength of several adhesive systems to different dentin depths [J].Am J Dent, 2003,16 (5):292-298.
  • 10Sano H, Shono T, Sonoda H, et al. Relationship between surface area for adhesion and tensile bond strength-evaluation of a micro-tensile bond test [J]. Dent Mater, 1994,10:236-240.

共引文献32

同被引文献8

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部