本文依据GB 6566-2010《建筑材料放射性核素限量》标准对某瓷砖的放射性进行测量,并对其结果进行不确定度分析,找出影响放射性测量结果的主要因素,量化不确定度分量,合成不确定度,最终给出该瓷砖放射性测量结果及其不确定度。通过本文对某瓷砖放射性测量的不确定度分析,对提高放射性测量的准确度具有参考意义。
The radioactivity of a tile is measured on the basis of code of GB 6566-2010 " Limits of radionuclides in building materials",and the results uncertainty is analyzed to find out the main factors influencing the radioactive measurement result,quantify uncertainty components,obtain the synthesis of uncertainty. Finally the radioactive measurement results and the uncertainty of the ceramic tile are given.It has reference significance for improving the radioactive measurement accuracy.