介绍了发电机转子回路接地的危害和配置转子接地保护的必要性,对工程常用的转子一点接地保护的原理和应用进行了分析,结合溪洛渡、向家坝大型水电机组转子一点接地保护的配置、应用以及整定计算等进行了探讨,说明了转子一点接地保护在溪洛渡、向家坝水电机组安全运行中的重要作用。
The necessity of rotor grounding protection is presented by introducing the potential damage caused by grounding of the generator rotor circuit .Several commonly used one-point rotor grounding protection are analyzed , inclu-ding their principles and applications .The configuration , application and setting calculation of such one-point rotor grounding protection in hydro-turbine generator units adopted in Xiluodu and Xiangjiaba hydropower stations are dis-cussed .Importance of the grounding protection for the safe operation of hydropower generator units are demonstrated .
出处
《水电与新能源》
2014年第11期1-4,12,共5页
Hydropower and New Energy
关键词
转子
一点接地
灵敏度
乒乓式
双端注入式
切换周期
rotor one-point grounding sensitivity ping-pong scheme double end injection switching cycle