期刊文献+

CT中不同对比剂注射方案对小型猪腹部大血管及肝脏强化模式的影响 被引量:5

Effect of different contrast media injection protocols on enhancement of abdomen major vessels and liver in swines in CT
下载PDF
导出
摘要 目的比较不同对比剂注射方案对小型猪腹部大血管及肝实质强化峰值及达峰时间的影响。方法对3头健康小型猪行3种方案交叉重复CT扫描,每组方案扫描6次,碘总量均为600mgI/kg体质量,A组:碘浓度270mgI/ml,注射流率3.4 ml/s,IDR 918 mgI/s;B组:碘浓度370 mgI/ml,注射流率2.5 ml/s,IDR 925 mgI/s;C组:碘浓度370mgI/ml,注射流率3.4ml/s,IDR 1258mgI/s。比较不同注射方案下腹主动脉、下腔静脉、门静脉主干、肝中静脉及肝实质的强化峰值及达峰时间,对图像强化效果进行评分。结果达峰时间腹主动脉C组小于B组,下腔静脉C组小于A和B组(P均<0.05),门静脉主干、肝中静脉和肝实质各组间差异均无统计学意义(P均>0.05);强化峰值腹主动脉、下腔静脉、门静脉主干和肝中静脉C组均大于A组和B组(P均<0.05),肝实质各组间差异无统计学意义(P均>0.05)。C组图像强化质量优于A组(P<0.05),余组间差异无统计学意义(P均>0.05)。结论对比剂IDR可影响猪腹部大血管强化峰值,碘总量一定时,肝实质强化模式不受对比剂碘浓度、注射流率及IDR的影响。 Objective To compare the intra-individual contrast enhancement of major vessels in the abdomen and liver parenchyma using different contrast enhancement injection protocols.Methods Three swines underwent CT scanning repeatedly in a cross-over method with three different contrast media injection protocols(n=6for each protocol)with a total iodine load of 600mg/kg,namely,group A:Contrast media concentration(CMC)270 mgI/ml,flow rate(FR)3.4 ml/s(iodine deliver rate[IDR]918mgI/s),group B:CMC 370,FR 2.5ml/s(IDR 925mgI/s)and group C:CMC 370,FR3.4ml/s(IDR 1258mgI/s).The time-to-peak enhancement and peak enhancement of abdominal aorta(AA),inferior vena cava(IVC),main portal vein(MPV),middle hepatic vein(MHV)and liver parenchyma,score of enhancement were compared between different groups.Results The time-to-peak enhancement of group C was earlier than that of group B in AA,and was earlier than that of group A and B in IVC(both P〈0.05).But there was no significant difference in the time-to-peak enhancement of MPV,MHV and liver parenchyma among group A,B and C(all P〉0.05).The peak enhancement of group C was higher than that of group A and B in AA,IVC,MPV and MHV(all P〈0.05),but there was no significant difference in the peak enhancement of liver parenchyma among group A,B and C(P〉0.05).The score of enhancement showed group C was better than group A(P〈0.05).But there were no significant differences between group A and B,B and C.Conclusion The peak enhancement of AA,IVC,MPV and MHV of swines is influenced by IDR,while the contrast enhancement of the liver parenchyma is not affected by CMC,IR and IDR when the total iodine load is kept constant.
出处 《中国医学影像技术》 CSCD 北大核心 2014年第12期1765-1768,共4页 Chinese Journal of Medical Imaging Technology
基金 国家自然科学基金面上项目(81271654) 广州市科技支撑项目(2010J-E481)
关键词 对比剂 体层摄影术 X线计算机 图像增强 腹部 Contrast media Tomography X-ray computed Image enhancement Abdomen
  • 相关文献

参考文献14

  • 1Cademartiri F, van der Lugt A, Luccichenti G, et al. Parametersaffecting bolus geometry in CTA : A review. J Comput Assist To-niogr, 2002, 26(4) : 598-607.
  • 2Guerrisi A, Marin D, Nelson RC, et al. Effect of varying con-trast material iodine concentration and injection technique on theconspicuity of hepatocellular carcinoma during 64-section MDCTof patients with cirrhosis. Br J Radiol, 2011, 84(1004) :698-708.
  • 3Mihl C, Wildberger JE, Jurencak T, et al. Intravascular en-hancement with identical iodine delivery rate using different iodinecontrast media in a circulation phantom. Invest Radiol, 2013, 48(11):813-818.
  • 4Behrendt FF, Plumhans C, Keil S, et al. Contrast enhancementin chest multidetector computed tomography: Intraindividualcomparison of 300 mg/ml versus 400 mg/ml iodinated contrastmedium. Acad Radiol, 2009,16(2) : 144-149.
  • 5Behrendt FF, Pietsch H, Jost G, et al. Identification of the io-dine concentration that yields the highest intravascular enhance-ment in MDCT angiography. AJR Am J Roentgenol, 2013, 200(5):1151-1156.
  • 6Behrendt FF, Pietsch H, Jost G, et al- Intra-individual compari-son of different contrast media concentrations (300 mg, 370 mgand 400 mg iodine) in MDCT. Eur Radiol, 2010, 20(7): 1644-1650.
  • 7Behrendt FF, Pietsch H, Jost G, et al. Low-osmolar monomericversus iso-osmolar dimeric contrast media : An intra-individualcomparison in CT angiography using an animal model. J Med Ima-ging Radiat Oncol, 2011,55(2):170-175.
  • 8Kim EY, Yeh DW, Choe YH, et al. Image quality and attenua-tion values of multidetector CT coronary angiography using high i-odine-concentration contrast material : A comparison of the use ofiopromide 370 and iomeprol 400. Acta Radiol, 2010, 51(9): 982-989.
  • 9Awai K, Inoue M, Yagyu Y, et al. Moderate versus high concen-tration of contrast material for aortic and hepatic enhancement andtumor-to-liver contrast at multi-detector row CT. Radiology,2004,233(3):682-688.
  • 10王广谊,梁长虹,刘红军,黄飚.低流率团注高浓度对比剂在兔脑CTA成像中的效果[J].中国医学影像技术,2009,25(2):195-197. 被引量:5

二级参考文献8

共引文献4

同被引文献40

  • 1张龙江,祁吉.对比剂肾病:一个值得关注的问题[J].中华放射学杂志,2007,41(8):882-884. 被引量:69
  • 2刘于宝,巫梓斌,茹光藤,梁长虹.64排螺旋CT不同剂量对比剂到达腹主动脉峰值时间的初步研究[J].实用放射学杂志,2007,23(11):1475-1477. 被引量:10
  • 3Guerrisi A, Marin D, Nelson RC, et al. Effect of varying contrast ma- terial iodine concentration and injection technique on the conspicuity of hepatocellular carcinoma during 64 - section MDCT of patients with cirrhosis[Jl. BrJ Radiol, 2011, 84(1004): 698-708.
  • 4Loukas M, Hullett J, Wagner T, et al. Clinical anatomy of the inferi- orphrenie artery[J]. ClinAnat, 2005, 18(5): 357 -365.
  • 5Kim HC, Chung JW, Park JH, et al. Transcatheter arterial ehemoem- bolization for hepatocellular carcinoma: prospective assessment of the right inferior phrenie artery with C -arm CT[ J]. J Vase Inter Radi- ol, 2009, 20(7) : 888 -895.
  • 6Miyayama S, Yamashiro M, Shibata Y, et al. Arterial blood supply to the caudate lobe of the liver from the proximal branches of the right in- ferior phrenie artery in patients with recurrent hepatocellular carcinoma after chemoembolization[ Jl. Japanese J Radiol,2012,30( 1 ) :45 -52.
  • 7Gokan T, Hashimoto T, Matsui S, et al. Helical CT demonstration ofdilated right inferior phrenic arteries as extrahepatic collateral arteries of hepatocellular carcinomas[ J]. J Comput Assist Tomogr, 2001, 25 : 68 -73.
  • 8Cademartiri F, van der Lugt A, Luccichenti G, et al. Parameters af- fecting bolus geometry in CTA:A review [ J]. J Comput Assist To- mogr, 2002, 26(4) : 598 -607.
  • 9Behrendt FF, Pietsch H, Jost G, et al. Low - osmolar monomeric ver- sus iso - osmolar dimeric contrast media : An intra - individual compa- rision in CT angiography using an animal model[ J]. J Med Imaging Radiat Oncol, 2011, 55(2) : 170 -175.
  • 10Mahnken AH, Jost G, Seidensticker P, et al. Contrast timing in com- puted tomography: effect of different contrast media concentrations on bolus geometry[ J]. Eur J Radiol, 2012, 81 (4) : e629 - e632.

引证文献5

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部