期刊文献+

换热器管板孔内不开槽的强度胀接 被引量:2

Strength expanding of trenchless of tube sheet hole in heat exchanger
下载PDF
导出
摘要 工业冷冻机组和中央空调水冷冷水机组用换热器的换热管通常有钢管、铜管、铜镍管和钛管等,其与管板的连接方式采用强度胀接的方式。传统的管板与换热管的强度胀接是通过在管板孔内开若干条胀管槽实现的。本文根据管板孔内不开槽的强度胀接工艺试验和实际生产中的应用情况,说明换热管与管板的强度胀接也可通过管板孔内不开槽和加胀管胶水实现。 The heat exchange tubes of heat exchanger used for industrial refrigeration unit and the central air-conditioning water cooled chiller are steel tubes, copper tubes, copper-nickel tubes and titanium tubes, etc. Their connections to the tube sheet uses the method of strength expanding. Traditionally, these connections are realized through a number of expanding tube's grooves inside the heat exchanger tube sheet hole. It is verified that the strength expanding between the exchange tube and tube sheet can be realized through trenchless of tube sheet hole with expanding tube glue, based on the engineering test about strength expanding of trenchless of tube sheet hole and its practical production application.
作者 王凤超
出处 《制冷与空调》 2014年第10期68-69,24,共3页 Refrigeration and Air-Conditioning
关键词 冷水机组 换热器 换热管 管板孔 不开槽 强度胀接 water chiller heat exchanger heat exchange tube tube sheet hole trenchless strength expanding
  • 相关文献

参考文献5

  • 1GB151-1999.管壳式换热器[S].[S].北京:国家质量技术监督局,1999..
  • 2毛希澜.换热器设计[M].上海:科学技术出版社,1998:526-533.
  • 3上海化学工业设计院.换热器[M].上海:科学技术出版社,1994:322-327.
  • 4TSGR0004-2009,固定式压力容器安全技术监察规程[S].
  • 5王刚.换热器管子与管板胀接工艺分析[J].青海大学学报(自然科学版),2004,22(2):36-38. 被引量:9

二级参考文献3

  • 1毛希澜.换热器设计[M].上海:科学技术出版社,1998.526-533.
  • 2换热器.上海化学工业设计院[M].上海:科学技术出版社,1994.322-327.
  • 3姚慧珠 郑海泉.化工机械制造[M].北京:化学工业出版社,1998.178-180.