期刊文献+

钛网在颈椎前路重建中的应用 被引量:3

Application of Titanium Mesh Cage Combined with Cervical Locking Plate in the Reconstruction of Anterior Cervical Spines
下载PDF
导出
摘要 目的评价钛网在颈椎疾患前路重建中的初步临床应用结果.方法 32例颈椎疾病患者行前路颈椎椎体次全切除,根据椎体病变不同分别以钛网载入所切椎体松质骨、同种异体脱钙骨或骨水泥进行颈椎前路重建手术,对临床结果进行疗效评定及影像学分析.结果 平均手术时间60( 40~80)min,平均手术出血80(50~120)ml,平均住院天数5(4~6)d,术后随访时间6~12月,所有病人颈部疼痛和神经症状术后均得到改善,术后影像学资料提示钢板及钛网位置良好,无内固定松动和脱出.无神经、血管并发症.结论 钛网在颈椎疾患前路重建中,可达到安全、有效的即时稳定作用,并可避免取髂骨所带来的并发症,且住院时间短,有利于病人的早期下床活动和功能恢复.
出处 《医学临床研究》 CAS 2002年第2X期92-94,共3页 Journal of Clinical Research
  • 相关文献

参考文献10

  • 1Caspar F,Geisler FH,Pitzen T,et a1.Anterior cervical platestabilization in one- and two-level degenerative disease:overtreatment or benefit[J]. JSpinal Disord,1998,11:1-11.
  • 2schneeberger AG, Boos N, Schwarzenbach O, et al. Anterior cervical interbody fusionwith plate fixation for chronic spondylotic radiculopathy: A 2-to 8-year follow-up[J]. JSpinal Disord, 1999, 12 :215-220.
  • 3Farey ID, McAfee PC, Davis RF, et al. Pseudoarthrosis of the cervical spine afteranterior arthrodesis[J] . J Bone Joint Surg(Am), 1990, 72: 1171-1177
  • 4Bohlman HH, Emery SE, Goodfellow DB, et al. Robinson anterior cervical discectomyand arthrodesis for cervical radiculopathy. Long-term follow-up of one hundred andtwenty-two patients[J] . J Bone Joint Surg, 1993, 75 : 1298-1307.
  • 5Goffin J,Loon JV,Calenbergh FV,et al.Long-term results after anterior cervicalfusion and osteosynthetic stabilization for fracture and /or dislocation of the cervicalspine[J].J Spinal Disord,1995,8:500-508.
  • 6Farey ID,McAfee PG,Devis RF,et al.Pseudoarthrosis of the cervical spine afteranterior arthrodesis:treatment by posterior nerve-root decompression,stabilization,andarthrodesis[J].J Bone Joint Surg(Am),1990,72:1171-1121.
  • 7Cook SD, Dalton JE, Tan EH. In vivo evaluation of anterior cervical fusions withhydroxylapatite graft material[J]. Spine, 1994,19(6): 1856-1866.
  • 8Kaushik DA, William T, Couldwell . Use of cylindrical titanium mesh and lockingplates in anterior cervical fusion[J].J Neurosurg(Spine), 2001, 94: 174-178.
  • 9毛志国,袁文,贾连顺,欧阳钧,王柏川,樊仕才.钛质网笼内植物加前路带锁钢板对颈椎稳定性的生物力学评价[J].中国脊柱脊髓杂志,2001,11(6):355-357. 被引量:56
  • 10王冰,吕国华,马泽民,康意军,李晶,李启贤.前路钉板系统在颈椎骨折脱位早期手术中的应用[J].湖南医科大学学报,2001,26(5):480-482. 被引量:12

二级参考文献5

共引文献63

同被引文献25

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部