期刊文献+

苯海拉明麻黄碱滴鼻液的质量标准研究 被引量:4

Quality Standard for Diphenhydramine and Ephedrine Nasal Drops
下载PDF
导出
摘要 目的建立苯海拉明麻黄碱滴鼻液的质量控制方法。方法采用HPLC法测定滴鼻液中盐酸苯海拉明和盐酸麻黄碱的含量;色谱条件:色谱柱以氰基键合硅胶为填充剂;流动相为乙腈-水-三乙胺(50∶50∶0.5)(用冰醋酸调节pH值至6.5);流速1 ml·min^-1;检测波长258 nm。结果化学反应和HPLC能检出盐酸苯海拉明和盐酸麻黄碱。在上述色谱条件下,盐酸苯海拉明和盐酸麻黄碱获得良好分离;进样浓度分别在0.0499~0.3996 mg·ml^-1(r=0.9999,n=5),0.2000~1.6002 mg·ml^-1(r=0.9999,n=5)范围内与峰面积呈良好的线性关系。盐酸苯海拉明平均回收率为100.0%,RSD为0.4%(n=9)。盐酸麻黄碱平均回收率为99.68%,RSD为0.4%(n=9)。结论本方法准确,重复性好,可作为苯海拉明麻黄碱滴鼻液的质量控制方法。 Objective To establish a method for quality control of Diphenhydramine and Ephedrine Nasal Drops. Methods The chromatographic conditions included the CN column (200 mm × 4.6 mm ,5 μm) and acetonitrile- water-triethylamine (50: 50: 0.5)(the pH was adjusted to 6.5 with glacial acetic acid) as the mobile phase ,The flow rate was 1.0 ml -min - 1 and monitored at 258 nm. Results Diphenhydramine hydroehloride and ephedrine hydroehlo- ride were identified by chemical reaction methods and HPLC. They were well separated. The calibration curve of di- phenhydramine hydrochloride and ephedrine hydroehloride was linear in the range of 0.0499 - 0. 3996 mg .ml^-1 ( r = 0. 9999, n =5)and 0.2000-1. 6002 mg .ml^-1( r = 0.9999, n = 5 ). The average recovery was 100.0% with an RSD of 0.4% ( n = 9) and 99.68% with an RSD of 0.4% ( n = 9) respectively. Conclusion This method is accu- rate and reproducible. It can be used as a reliable method for quality control of Diphenhydramine and Ephedrine Nasal Drops.
出处 《解放军药学学报》 CAS 2014年第5期428-430,共3页 Pharmaceutical Journal of Chinese People's Liberation Army
基金 军队医疗机构制剂标准提高科研专项重点课题 No.13ZJZ07
关键词 盐酸苯海拉明 盐酸麻黄碱 NHPLC diphenhydramine hydrochloride ephedrine hydrochloride NHPLC
  • 相关文献

参考文献4

二级参考文献13

共引文献8

同被引文献33

引证文献4

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部