期刊文献+

改良电休克治疗术后呼吸暂停恢复时间的影响因素 被引量:2

Influencing factors of apnea time after modified electroconvulsive treatment
下载PDF
导出
摘要 目的:探讨改良电休克治疗(MECT)术后呼吸暂停恢复时间的影响因素。方法:对210例有MECT适应证的精神病患者进行MECT治疗,术前收集患者的一般资料、所用抗精神病药种类、张口度、Mallampati气管分级、首次MECT的各项参数、麻醉剂用量以及术后呼吸暂停恢复时间。根据术后呼吸暂停恢复时间划分为:≤5 min组169例和>5 min组41例;分析呼吸暂停恢复时间延长的影响因素,建立多重线性逐步回归模型。结果:多重线性回归分析显示,自变量血红蛋白水平(β=-0.053,t=-7.049;P=0.000)、张口度(β=1.206,t=4.395;P=0.000)、气管分级(β=0.988,t=3.407;P=0.001)及抗精神病药种类(β=0.406,t=3.037;P=0.003)可以解释术后呼吸暂停恢复时间延长的67.4%的变异,该模型的矩阵拟合性较好。结论:MECT术后呼吸暂停恢复时间延长与多种因素有关。 Objective:To explore the influencing factors of apnea time after modified electroconvulsive thera-py( MECT). Method:A total of 210 psychotic patients who met the indications of MECT received the MECT.The data of patients′general information,using the types of antipsychotic drugs,mouth opening degree( MO),mallampati classification(MMC),MECT parameters for the first time,the dosage of anesthetic and postoperative recovery time for sleep apnea were collected. All of the patients were divided into two groups according to the apnea time( less or equal to 5 min and above)after treatment.Multilinear stepwise regression analysis was performed to identify influen-cing factors associated with the prolonged recovered respiratory. Results:Multilinear stepwise regression analysis showed that the following factors were independent variables of the prolonged recovery respiratory after MECT:the level of hemoglobin(β = -0.053,t = -7.049,P =0.000 ),MO(β =1.206,t =4.395,P =0.000 ),MMC (β=0.988,t=3.407,P=0.001),and types of antipsychotics(β=0.406,t=3.037,P=0.003).These variables can explain 67.4% variations;and the model was appear to be fitting well. Conclusion:Various factors were associated with the prolonged recovered respiratory after MECT.
出处 《临床精神医学杂志》 2014年第6期411-412,共2页 Journal of Clinical Psychiatry
关键词 改良电休克治疗 呼吸暂停 影响因素 modified electroconvulsive therapy apnea influencing factors
  • 相关文献

参考文献6

  • 1沈渔邨.精神病学[M].5版.北京:人民卫生出版社.2009:838.
  • 2Bloch Y,Pollack M,Mor I. Should the administration of ECT duringclozapine therapy be contraindicated? [ J ]. Br J Psychiatry,1996,169:253-254.
  • 3谢勇,梅海翔,胡建英,樊正秀,曹奕.无抽搐电休克治疗致呼吸恢复延长者的药物使用研究[J].中华精神科杂志,2003,36(2):91-93. 被引量:16
  • 4吴孟超等.黄家驷外科学[M].6版.北京:人民卫生出版社,2000:166-180.
  • 5McCall WV, Arias L,Onafuye R,et al. What the electroconvulsivetherapy practitioner needs to know about obstructive sleep apnea[J].J ECT,2009,25 :50-53.
  • 6Rishi MA,Shetty M, Wolff A,et al. Atypical antipsychotic medica-tions are independently associated with severe obstructive sleep ap-nea[ J]. Clin Neuropharmacol,2010,33 : 109-113.

二级参考文献3

  • 1沈渔Cun 主编.精神病学第4版[M].北京:人民卫生出版社,2001.734-735.
  • 2Hinkes R, Quesada TV, Currier MB, et al. Aspiration pneumonia possibly secondary to clozapine-induced sialorrhea. J Clin Psychopharmacol, 1996, 16: 462-463.
  • 3汪卫华,王焕林,刘维莉,苏宗荣,孙剑,严志康,艾永林,高峰.氯氮平所致“类感染综合症”的临床研究[J].中国神经精神疾病杂志,2001,27(4):267-269. 被引量:14

共引文献263

同被引文献8

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部