结合成都地铁2号线西延线机电设备联调的数据统计和分析,对西延线联调常见故障问题的原因进行了分析,包括对"车站双向进出站闸机与导向联动错误"、"列车到站广播不正"、"乘客信息系统显示目的地问题"等故障问题进行了分析,并给出了解决方法。
Combining with the integrated joint debugging data of the electro-mechanical equipment used on the West extension of Chengdu Metro Line 2,the reaosns for common faults are analyzed,including the two-way access gates and steering linkage erros at metro station,the train arrival broadcasting mistakes and the wrong destination display in passenger information system,etc.,some suggestions and solusions are proposed.