期刊文献+

改进Smith控制在主汽温控制上的应用研究

Application of an improved smith control on the main steam temperature
下载PDF
导出
摘要 针对电站主汽温难控问题,尝试使用一种改进Smith补偿控制器,并应用多容惯性标准传递函数方法进行改进Smith补偿控制器的辅助控制器参数整定。结果表明:改进Smith补偿控制器用于电站锅炉主汽温控制是可行的并且比常规的PID控制在最优性和鲁棒性上优势明显;应用多容惯性标准传递函数方法进行辅助控制器参数整定是一种有效的易操作的参数整定方法。 Considering the problem that the power plant main steam temperature is hard to control, this paper tries to use an improved Smith compensation controller, and the multiple capacity process transfer function standard method for parameter tuning of secondary controller. The result show the application of improved Smith compensation controller for the power plant boiler main steam control is feasible, and there is obvious advantage on the optimality and robustness, compared to conventional PID control; application of multiple capacity process transfer function standard for secondary controller parameter tuning is an effective and easy-operated parameter tuning method.
出处 《信息技术》 2014年第12期106-109,共4页 Information Technology
基金 上海市"科技创新行动计划项目"(13111104300) 上海市电站自动化技术重点实验室(13DZ2273800)
关键词 迟延补偿 电站锅炉 汽温 控制器 参数整定 delay compensation power plant boiler steam temperature controller parameter tuning