摘要
采用广义最小方差对火电机组控制回路进行性能评估,并使用潜能指标和相对潜能指数来监控回路整定后的性能变化情况。仿真结果表明,使用广义最小方差能很好地对火电机组控制系统进行性能评估。
In this paper,the generalized minimum variance is used for performance assessment of a thermal power unit control loop. The potential index and relative potential index are used to monitor the change of the closed-loop potential after tuning. The simulation results show that the generalized minimum variance can assess the performance of the thermal power unit control system well.
出处
《江南大学学报(自然科学版)》
CAS
2014年第6期711-715,共5页
Joural of Jiangnan University (Natural Science Edition)
关键词
火电机组
性能评估
广义最小方差
闭环潜能
相对闭环潜能指标
thermal power unit, performance assessment, generalized minimum variance, closed-loop potential,relative closed-loop potential index