摘要 水听器作为测试基本物理量声压的设备,被广泛应用于医疗超声的声场测试中。但是由于水听器具有指向性,水听器与超声换能器的夹角会给声场的测试引入一定的误差。为了保证测试的准确度,有必要对水听器的指向性进行测试与研究。在本试验中,我们针对同一个给定的HIFU换能器分别测试了针式水听器、膜式水听器和鲁棒水听器。实验结果表明水听器指向性具有一定的不对称性,这个是由于制造工业等原因造成的。因此,沿着一个轴的方向测试水听器的指向性是不能满足测试需求的。在描述HIFU声场的时候,有必要校正水听器的指向性。 Hydrophone has been widely used in testing ultrasonic field distribution.But the hydrophone has a certain directivity,which may bring error in the actual acoustic field measurements.So it is necessary to meet some requirements about the directivity of hydrophone.In the measurement,the spatial directivities of needle hydrophone,membrane hydrophone and robust hydrophone is measured and a comparison about measured data of HIFU acoustic field with them is given.Experimental results indicate that the asymmetric special directivity of hydrophone is due to manufacturing processes and other reasons.As a result,it is not sufficient to test the directivity of hydrophone along one axis.It is necessary to adjust the direction of the hydrophone when characterizing the HIFU field.
作者 林涛 陈涛
出处 《中国医疗器械信息》 2014年第12期61-65,共5页 China Medical Device Information
关键词 水听器 高强度聚焦超声 应用 hydrophone HIFU application
  • 相关文献

参考文献4

二级参考文献29

  • 1汪钱纯,叶险峰,曹永良,占丽媛.用布拉格光纤光栅对聚焦超声场的检测[J].传感技术学报,2005,18(1):171-173. 被引量:6
  • 2许坚毅.水柱法测量HIFU的声场[J].声学技术,2001,20(01):302-304.
  • 3Claudio I Zanelli,Samuel M Howard.A Robust Hydrophone for HIFU Metrology.5th International Symposium on Therapeutic Ultrasound,2006
  • 4Staudenraus J,Eisenmenger W.Fiber-optic probe hydrophone for ultrasonic and shock-wave measurements in water.Ultrasonics,1993:31 (4):267 -273
  • 5Ch Koch.Coated fiber optic hydrophone for ultrasonic measurement[J].Ultrasonics,1996,34 (6):687 -689
  • 6Christian Koch.Measurement of ultrasonic pressure by heterodyne interferometry with a fiber-tip sensor[J].Applied Optics,1999,38 (13):2812 -2819
  • 7Yunqiu Wu,Shankar P M,Lewin P A,et al.Fiber optic ultrasonic sensor using Raman-Nath light diffraction.Ultrasonics,Ferroelectrics and Frequency Control,IEEE Trans,1994,42(2):166 -171
  • 8Servant G,Laborde J L,Hita A.Spatio-temporal dynamics of cavitation bubble clouds in a low frequency reactor:comparison between theoretical and experimental results[J].Ultrasonics Sonochemistry,2001(8):163 - 174
  • 9Lynn J G,Zwemer R L,et al.A new method for generation and use of focused ultrasound in experimental biology[J].J Gen Physiol,1942,26:179
  • 10Fry W J,Mosberg W H Jr,Barnard J W,et al.Production of focal destructive lesions in the central nervous system with ultrasound[J].J Neurosurg,1954,11(5):471 -478