摘要 目的探讨估测右颈内静脉前路法置管长度最适宜的公式。方法选取2013年1月至2013年6月我科经右颈内静脉留置深静脉导管患者67例,分别用4种公式对置入导管长度进行估测,并与实际置入至正确位置的长度进行比较,分析4种公式的准确性。结果 4种公式估测置入长度的误差百分比均在15%以内。公式1估测长度与实际长度无明显差异(P>0.05);其余3种公式的估测长度均明显小于实际长度,有明显差异性(P<0.05)。在对不同身高患者置管长度的预测中,公式4的平均绝对误差明显高于公式1,有明显差异性(P<0.05);公式2、公式3与公式1的绝对误差平均值比较均无显著性差异(P>0.05)。结论4种公式预测长度误差均在15%以内,其中公式1简单、准确、实用、误差小,更适用于右颈内静脉置管前路法长度的估计。 Objective To explore the most effective formula to predict the catheterization length of the right internal jugular vein by an-terior approach. Methods Sixty-seven cases performed with right internal jugular vein catheterization from January 2013 to June 2013 were enrolled in this study and 4 formulas were selected to predict the catheterization lengths. Comparing their predicted lengths with the actual lengths defined as the lengths of the internal catheters which terminals were inserted to a accurate position,and analyse their predictive validi-ty. Results The predictive error percentages of the 4 formulas were all less than 15%. Comparing the predicted lengths and the actual lengths, there was no difference between the predicted length of the 1st formula and the actual one(P〉0. 05),and the predicted lengths of the other three formulas were significantly less than the actual ones(P0. 05). Conclusion The predictive error of all the 4 formulas is less than 15%, and the 1st formula is&nbsp;simple,practical and associated with a much smaller error,more suitable to estimate the length of the right internal jugular vein catheterization by anterior approach.
出处 《局解手术学杂志》 2014年第6期617-619,共3页 Journal of Regional Anatomy and Operative Surgery
关键词 颈内静脉置管 长度 计算公式 internal jugular vein catheterization length formula
  • 相关文献

参考文献13

  • 1段波,黄胜,刘峰,欧媛媛,罗兴进,徐丹青.经右侧颈内静脉放置中心静脉导管置入深度的简易计算公式[J].临床麻醉学杂志,2012,28(8):790-791. 被引量:11
  • 2邹素珍,张国花,周桂娅.经颈内静脉穿刺上腔静脉置管长度的探讨[J].中华护理杂志,1998,33(6):340-341. 被引量:28
  • 3Peres PW.Positioning central venous catheters--a prospective survey[J].Anaesth Intensive Care,1990,18(4):536-539.
  • 4Pérez Valdivieso JR,Mbongo Bubakala C,Honorato Cía C,et al.Evaluation of a formula for optimal positioning of a central venous catheter through the right internal jugular vein[J].Rev Esp Anestesiol Reanim,2003,50(2):77-79.
  • 5Connolly B,Mawson JB,Mac Donald CE,et al.Fluoroscopic landmark for SVC-RA junction for central venous catheter placement in children[J].Pediatr Radiol,2000,30(10):692-695.
  • 6Lennon M,Zaw NN,Ppping DM,et al.Procedural complications of central venous catheter insertion[J].Minerva Anestesiol,2012,78(11):1234-1240.
  • 7柏树令,应大君.系统解剖学[M].第8版.北京:人民卫生出版社,2013:291-294.
  • 8Joshi AM,Bhosale GP,Parikh GP,et al.Optimal positioning of right-sided internal jugular venous catheters:comparison of intra-atrial electrocardiography versus Peres’formula[J].Indian J Crit Care Med,2008,12(1):10-14.
  • 9Kim WY,Lee CW,Sohn CH,et al.Optimal insertion depth of central venous catheters--is a formula required?A prospective cohort study[J].Injury,2012,43(1):38-41.
  • 10Andropoulos DB,Bent ST,Skjonsby B,et al.The optimal length of insertion of central venous catheters for pediatric patients[J].Anesth Analg,2001,93(4):883-886.

二级参考文献39

  • 1周和清,扬蓓.PICC的X线分析[J].实用医技杂志,2005,12(08A):2009-2010. 被引量:57
  • 2毛庆祥,胡弋,马永达,刘宿,杜权,葛衡江.ECG深静脉置管深度定位的临床应用[J].重庆医学,2006,35(20):1895-1896. 被引量:2
  • 3Nishio R,Ohhigashi S,Inoue H, Sakurai S, Nishio T, Onodera H. Reappraisal of the usefulness of peripherally inserted central venous eatheters[J]. Nihon Rinsho Geka Gakkai Zasshi (J Jpn Surgi Associat), 2008,69 : 1-6.
  • 4DeChicco R,Seidner D L, Brun C, Steiger E, Stafford J, Lopez R. Tip position of long-term central venous access devices used for parenteral nuttrition[J]. JPEN J Parenter Enteral Nutr, 2007,31 : 382-387.
  • 5Markovich M B. The expanding role of the infusion nurse in radiographic interpretation for peripherally inserted central catheter tip placement[J]. J Infus Nurs,2008,31:96-103.
  • 6Stonelake P A, Bodenham A R. The carina as a radiological landmark for central venous catheter tip position[J]. Br J Anaesth,2006,96 : 335-340.
  • 7Fricke B L,Racadio J M,Duekworth T,Donnelly L F,Tamer R M, Johnson N D. Placement of peripherally inserted central catheters without fluoroscopy in children: initial catheter tip position[J]. Radiology , 2005, 234: 887-892.
  • 8Steiger E, the HPEN Working Group. Consensus statements regarding optimal management of home parenteral nutrtion (HPN) access[J]. Parenter Enteral Nutr,2006,30(Suppl) :94- 95.
  • 9Lueas H, Attard-Montalto S P, Saha V, Bristow A, Kingston J E,Eden O B. Central venous catheter tip position and malfunction in a paediatric oncology unit[J]. Attard Montalto Pediatr Surg Int, 1996,11: 159-163.
  • 10Wise M,Richardson D, Lure P. Catheter tip position: A sign of things to come[J]. J Vase Access Devices Summer,2001:18 - 27.

共引文献88

同被引文献2

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部