摘要 目的探讨脑电双频指数(BIS)评价儿童重症监护室(PICU)机械通气患儿镇静程度的可靠性和有效性。方法选择接受机械通气治疗的患儿19例,均在机械通气后5~15 min内静脉推注咪达唑仑,直至达到镇静目标。设定镇静目标为BIS值60~80,分别记录达镇静目标后30、60和120 min的吸氧浓度(Fi O2),经皮血氧饱和度(Sp O2)以及BIS、镇静躁动(SAS)和Ramsay镇静量表(RSS)3种镇静评分,并对3种评分进行相关性分析。结果 19例患者均达镇静目标,患者镇静后Fi O2较镇静前显著下降,Sp O2显著升高(P〈0.05);BIS值与主观评分间相关性良好,其中BIS值与RSS评分呈显著负相关(r=-0.650,P〈0.05),与SAS评分呈显著正相关(r=0.626,P〈0.05)。结论用BIS监测评估机械通气患者镇静深度简单方便、同步有效,是评价ICU机械通气患者镇静深度的良好客观指标。 Objective To explore the feasibility and efficiency of bispectral index(BIS) monitor for assessing the sedation level of mechanically ventilated patients in the Pediatric Intensive C are Unit(PICU).Methods A total of 19 patients who underwent mechanical ventilation were selected.Patients were intravenously injected with midazolam 5-15 min after mechanical ventilation until the BIS score reached 60-80.Then after 30,60,and120 min,the concentration of oxygen inhalation(FiO2),transcutaneous oxygen saturation(SpO2),and values and scores of BIS,sedation-agitation scale(SAS),and Ramsay sedation scale(RSS) were recorded.The correlation of three sedation scales was analyzed.Results All patients were sedated.After being sedated,FiO2of patients significantly decreased and SpO2 significantly increased(P〈0.05).BIS value was significantly correlated with subjective scores.BIS value was significantly and negatively correlated with RSS scores(r=-0.650,P 〈0.05) and significantly and positively correlated with SAS scores(r =0.626,P〈0.05).Conclusion BIS monitor is a simple and efficient method to assess the sedation level of mechanically ventilated patients and an ideal objective index for assessing the sedation level of mechanically ventilated patients in ICU.
出处 《上海交通大学学报(医学版)》 CAS CSCD 北大核心 2014年第12期1796-1799,共4页 Journal of Shanghai Jiao tong University:Medical Science
关键词 脑电双频指数 镇静躁动评分 机械通气 镇静 bispectral index sedation-agitation scale mechanical ventilation sedation
  • 相关文献

参考文献16

  • 1重症加强治疗病房病人镇痛和镇静治疗指南(2006)[J].中国实用外科杂志,2006,26(12):893-901. 被引量:215
  • 2Yiliaz C, Kelebek Girgin N, Ozdemir N, et al. The effect of nursing-implemented sedation on the duration of mechanical ventila- tion in the ICU[J]. Ulus Travma Acil Cerralli Derg, 2010, 16(6) : 521 -526.
  • 3Jackson DL, Proudfoot CW, Cann KF, et al. A systematic review of the impact of sedation practice in the ICU on resource use,costs and patient safety[J]. Crit Care, 2010, 14(2) : R59.
  • 4Kasuya Y, Govinda R, Rauch S, et al. The correlation between bis- pectral index and observation al sedation scale in volunteers sedated with dexmed etomidine and propofol[ J]. Anesth Analg, 2009, 109 (6) : 1811 - 1815.
  • 5Winterhalter M, Munte S, Taschenbrecker P, et al. Skin impedance correlates to sedation grade, plasma propofol concent rations and bispectral index during a target-controlled infusion of propofol [ J ].Eur J Anaesthesiol, 2009, 26 (7) : 589 - 596.
  • 6Hemmerling TM, Charabati S, Zaouter C, et al. A randomized con- trolled trial demonstrates that a novel closed-loop propofol system performs better hypnosis control than manual administration [ J ]. Can J Anaesth, 2010, 57(8) : 725 -735.
  • 7Liu N, Chazot T, Hamada S, et al. Closed-loop coadministration of propofol and remifentanit guided by bispectral index: a randomized multicenter study[J]. Anesth Analg, 2011, 112(3): 546 -557.
  • 8Avidan MS, Zhang L, Burnside BA, et al. Anesthesia awareness and the bispectral index[J]. N Engl J Med, 2008, 358(11) : 1097 - 1108.
  • 9Yamashita K, Terao Y, Inadomi C, et al. Age-dependent relation- ship between bispectral index and sedation level[ J]. J Clin Anesth, 2008, 20 (7) : 492 - 495.
  • 10Karamchandani K, Rewari V, Trikha A, et al. Bispectral index correlates well with Richmond agitation sedation scale in mechanical- ly ventilated critically ill patients [ J ]. J Anesth, 2010, 24 (3) : 394-398.

二级参考文献19

  • 1王晓敏,赵津生.咪唑安定在PICU的应用[J].实用药物与临床,2005,8(2):63-64. 被引量:8
  • 2于布为.麻醉深度监测进展[J].中国医疗器械信息,2005,11(6):5-10. 被引量:16
  • 3马朋林,赵金柱,苏瑾文,李秦,王宇.脑电双频指数与镇静-躁动评分评价机械通气患者镇静程度可靠性的比较研究[J].中国危重病急救医学,2006,18(6):323-326. 被引量:37
  • 4顾勤,刘宁,葛敏,高伟.脑电双频指数监测在重症加强治疗病房机械通气患者镇静中的应用[J].中国危重病急救医学,2007,19(2):101-103. 被引量:42
  • 5Jacobi J, Fraser GL, Coursin DB, et al. Clinical Practice guidelines for the sustained use of sedatives and analgesics in the critically ill adult. Crit Care Med,2002,30( 1 ) : 119-141.
  • 6Ramsay M, Savege T, Simpson BRJ, et al. Controlled sedation with alphaxalone-alphadolone. Br Med J,1974,22 (2) :656-659.
  • 7Riker RR, Picard JT, Fraser GL. Prospective evaluation of the Sedation-Agitation Scale for adult critically ill patients. Crit Care Med,1999,27 (7) :1325-1329.
  • 8Aneja R, Heard AM, Fletcher JE, et al. Sedation monitoring of children by the bispectral index in the pediatric intensive care unit. Pediatr Crit Care Med,2003,4( 1 ) :60-64.
  • 9Berkenbosch JW,Fichter CR,Tobias JD,et al. The correlation of the bispectral index monitor with clinical sedation scores during mechanical ventilation in the pediatric intensive care unit. Anesth Analg ,2002,94 (3) :506-511.
  • 10Vivien B, Paqueron X, Le-Cosquer P, et al. Detection of brain death onset using the bispectral index in severely comatose patients. Intensive Care Med ,2002,28 (4) :419-425.

共引文献239

同被引文献79

  • 1乐建威,莫国民,林敏.麻醉镇静深度的脑电双谱指数监护技术[J].中国医疗器械杂志,2005,29(5):321-324. 被引量:15
  • 2急性肺损伤/急性呼吸窘迫综合征诊断和治疗指南(2006)[J].中华急诊医学杂志,2007,16(4):343-349. 被引量:305
  • 3Vretzakis G, Ferdi E, Argiriadou H, et al. Influence of bispectral index monitoring on decision making during cardiac anesthesia. J Clin Anesth ,2005,17 (7) : 509 - 516.
  • 4Rosow C, Manberg PJ. Bispectral index monitoring. Anesthesinl Clin North America, 2001,19 (4) :947 - 966.
  • 5Kerssens C, Klein J, van der Woerd A, et al. Auditory information processing during adequate propofol anesthesia monitored by electroencephalogram bispectral index. Anesth A nalg,2001,92 (5) : 1210 - 1204.
  • 6Faraoni D, Salengros JC, Engelman E, et al. Ketaminc has noeffect on bispectral index during stable prapofol-remifentanil anesthesia. Br J Anaesth ,2009,102(3 ) :336 - 339.
  • 7Gupta M, Shri I, Sakia P, et al. Comparison of equi-minimum alveolar concentration of sevoflurane and isoflurane on bispectral index values during both wash in and wash oat phases:a prospective randomised study. Indian J Anaesth ,2015,59 (2) :79 -84.
  • 8Detsch O, Schneider G, Kochs E, et al. Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients. Br J Anaesth,2000,84( 1 ) :33 -37.
  • 9Ozcan MS, Ozcan MD, Khan QS, et al, Does nitrous oxide affect bispectral index and state entropy when added to a propofol versus sevoflurane anesthetic? J Neurosurg Anesthesiol, 2010, 22 ( 4 ) : 309 -315.
  • 10Coste C, Guinard B, Menigaux C, et al. Nitrous oxide prevents movement during orotracheal intubation without affecting BIS value. Anesth Analg,2000,91 (1) :130 - 135.

引证文献7

二级引证文献64

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部