摘要
本文通过对末级过热器出口集箱连接管爆管进行原因分析,得出钢管在出厂前就已经存在内壁裂纹的结论,进一步分析了此类内壁裂纹漏检的原因。
Cause analysis is carried on the burst and leakage at the linking tube of final super- heater outlet header in this paper,come a conclusion that the crack at the internal wall is obtained in the tube manufacturer. Analyze the reason why such crack without being detected successfully.
出处
《锅炉制造》
2015年第1期34-36,共3页
Boiler Manufacturing
关键词
末级过热器
裂纹
原因分析
final super-heater
crack
cause analysis