期刊文献+

印尼巴厘岛燃煤电厂主变压器变比选择

Selection of main transformer ratio of Indonesia Bali Island Coal-fired Power Plant
下载PDF
导出
摘要 介绍了印尼巴厘岛燃煤电厂项目的基本概况,核实了主变压器变比技术参数,发现了印尼国家电力公司提出的主变压器变比技术要求存在诸多矛盾,计算了主变压器变比,在与印尼国家电力公司进行了技术沟通后,修改了变压器技术参数的要求。 The general situation of the Indonesia Bali Island Coal-fired Power Plant was introduced. The technical parameters about the main transformer ratio were checked. It was found thatthere were some contradictions in the main transformer ratio technical requirement proposed by Indonesia National Electric Power Company. The ratio of the main transformer was calculated. Aiming at above problem,the project contractor communicated with Indonesia National Electric Power Company,and the requirement of technical parameters of the main transformer was amended.
作者 马洪涛
出处 《华电技术》 CAS 2014年第12期32-34,37,共4页 HUADIAN TECHNOLOGY
关键词 巴厘岛燃煤电厂 主变压器 变比 调压开关 Bali Island coal-fired power plant main transformer ratio tap changer
  • 相关文献

参考文献5

  • 1GB50660-2011大中型火力发电厂设计规范[S].2011.
  • 2DL/T 5153-2002,火力发电厂厂用电设计技术规定[S].
  • 3GB/T13499-2002,电力变压器应用导则[S].
  • 4吴俊勇,徐丽杰,郎兵,等.电力系统基础[M].北京:清华大学出版社.2008.
  • 5宋广哲,田秀俊.浅谈电厂接入系统设计中主变压器分接头的选择[c]//吉林省电机工程学会2007年论文集.长春:吉林省电机工程学会,2007:492-497.