期刊文献+

夏热冬冷地区混合式地源热泵系统控制策略 被引量:3

Control strategies of hybrid ground source heat pump system in hot-summer and cold-winter zone
下载PDF
导出
摘要 建立用于某办公建筑的冷却塔辅助散热型混合式地源热泵系统模型,以夏热冬冷气候条件下的长沙、上海和武汉地区为例,模拟混合地源热泵系统分别以地埋管出水温度、地埋管出水与环境温差、冷却塔运行时段作为辅助散热启停的控制信号的控制策略,运行20年后地埋管附近土壤平均温度及机组性能。研究各控制策略对不同地区的适用性。结果表明,3种控制策略在夏热冬冷地区的不同地区均表现出对系统能耗和土壤温升相近的影响规律,且均可以通过合理的参数设施实现运行20年后土壤维持热平衡。 A model of hybrid ground source heat pump(GSHP)system with the supplemental heat rejecter of cooling tower for an office building is established.Under various control strategies of taking buried pipes' outlet water temperature,temperature difference between buried pipes' outlet water and ambient temperature,and cooling tower operating period as the start-stop control signal of supplemental heat rejecter,the hybrid GSHP system is simulated to obtain the soil temperature around the buried pipes and the unit's performance in Changsha,Shanghai and Wuhan of hot-summer and cold-winter zones during twenty years operation.The applicability of all control strategies in different zones is studied.The results show that these three control strategies show similar law of effect on system's energy consumption and soil temperature rise for different hot-summer and coldwinter zones.All the control strategies can maintain underground heat balance after twenty years operation through setting the parameters reasonably.
出处 《制冷与空调》 2014年第12期127-131,共5页 Refrigeration and Air-Conditioning
基金 中央高校基本科研业务费专项资金资助项目(2010QZZD0105)
关键词 混合式地源热泵 冷却塔 控制策略 土壤热平衡 hybrid GSHP cooling tower control strategy soil heat balance
  • 相关文献

参考文献11

  • 1Mustafa Omer A. Ground-source heat pumps systems and applications[J]. Renewable and Sustainable Energy Reviews,2008,12(2) 344-371.
  • 2Chiasson A D, Yavuzturk C. A design tool for hybrid geo- thermal heat pump systems in cooling-dominated build- ings[J].
  • 3ASHRAE Transactions, 2009,115 (2) : 74-87. Spider J D. Editorial: Ground-source heat pump sys- tem research-past, present and future [J]. HVAC&R Research, 2005,11 (2) : 165-167.
  • 4李大鹏,饶政华,张翔,廖胜明.长沙地区多功能地源热泵系统的模拟与分析[J].中南大学学报(自然科学版),2013,44(3):1221-1227. 被引量:7
  • 5范蕊,高岩,陈旭,龙惟定.基于热平衡的土壤源热泵系统特性分析[J].同济大学学报(自然科学版),2011,39(2):282-286. 被引量:20
  • 6Ramamoorthy M, Jin H, Chiasson A D, e t al. Optimal sizing of hybrid ground-source heat pump systems that use a cooling pond as a supplemental heat rejeeter-a system simulation approach[J]. ASHRAE Transac- tions,2001,107 (1) :26-38.
  • 7Cenk Yavuzturk,Jeffrey D Spitler. Comparative study to investigate operating and control strategies for hy- brid ground source heat pump systems using a short time-step simulation model [J]. ASHRAE Transac- tions,2000,106(2) : 192-209.
  • 8王华军,赵军.混合式地源热泵系统的运行控制策略研究[J].暖通空调,2007,37(9):131-134. 被引量:29
  • 9姚灵锋,蔡龙俊.地源热泵热平衡问题的研究及工程应用[J].节能技术,2009,27(2):140-144. 被引量:28
  • 10Hellstorm G. Ground heat storage: thermal analyses of duct storage systems[D]. Sweden: Lunds University, 1991.

二级参考文献32

  • 1曾宪斌,李娟.地源热泵的地域特性及热平衡问题[J].能源技术,2007,28(6):347-349. 被引量:17
  • 2赵军,王华军.密集型桩埋换热器管群周围土壤换热特性的数值模拟[J].暖通空调,2006,36(2):11-14. 被引量:24
  • 3Federal energy management program, Assessment of Hybrid Geothermal Heat Pump Systems, 2008.
  • 4Jun Gao, Xu Zhang. Thermal performance and ground temperature of vertical pile - foundation heat exchangers: A case study. Applied Thermal Engineering, 2008, 28( 17 - 18) :2295 - 2304.
  • 5Yavuzturk C, Spitler J D. Comparative study of operating and control strategies for hybird ground source heat pump systems using a short time step simulation mode[ G]. ASHRAE Transactions, 2000, 106(2) : 192 - 209.
  • 6M.H. Khan, A. Varanasi, J.D. Spider, D.E. Fisher, R. D. Delahoussaye. Hybrid Ground Source Heat Pump System Simulation Using Visual Modeling Tool for HVACSIM + . Eighth International ISPSA Conference, 2003.
  • 7ASHRAE. Commercial/institutional ground source heat pump engineering manual [M]. Atlanta: American Society of Heating, Refrigerating and Air- Conditioning Engineers Inc, 1995.
  • 8Chiasson Andrew. Advances in modeling of ground-source heat pump systems[D]. Stillwater: Oklahoma State University, 1999.
  • 9Witte H J L, van Gelder A J, Serrao M. Comparison of design and operation of a commercial UK ground source heat pump project [EB/OL]. E2009-09-10 3. http://www, groenholland, com/nl/ publications/.
  • 10Witte H J L. Geothermal response tests with heat extraction and heat injection:examples of application in research and design of geothermal ground heat exchangers [ EB/OL ]. [ 2009-09-08 ]. www. groenholland, nl/download/Lausanne, witte, pdf.

共引文献89