摘要
通过对核电站用表冷器的设计分析,针对核电用表冷器的特殊使用要求,从表冷器框架材料、翅片材料、翅片结构形式、管束排布方式、抗震性能等方面进行了分析论述,确定了最优设计方案,经过制造及试验验证,符合预期的设计要求。
Based on the nuclear power station with a cooling coils design analysis, the special requirements for nuclear power cooling coil from cooling coils frame material, fin material, in the form of fin structure, tube bundle arranged manner, seismic performance, etc. were analyzed and discussed to determine the optimal design, through manufacturing and test verification, compliance with the design requirements.
出处
《洁净与空调技术》
2014年第4期69-72,共4页
Contamination Control & Air-Conditioning Technology
关键词
核电站
表冷器
翅片
管束排布
抗震
Nuclear power station
Cooling coils
Fin
Tube bundle arrangement
Seismic