期刊文献+

600MW汽轮机隔热罩的数值分析研究 被引量:2

Numerical Analysis Research on the Shrouds of the 600MW Steam Turbine
下载PDF
导出
摘要 600MW超临界汽轮机冷态启动过程中,经过汽轮机中压缸隔热罩的再热蒸汽温度由300℃升至538℃,压力从1MPa升至3.8MPa,所以避免隔热罩在这样不利的环境中受到损坏对于电厂来说是必要的。利用有限元分析软件绘制出中压缸隔热罩模型,接着分析冷态启动工况下温度场,应力场和综合应力场,找出所受到的应力最集中的部位,也就是启动中最危险的部位。 During the 600MW supercritical turbine startup process ,the temperature of the reheat steam passing through the shrouds of pressure cylinder rises from 300℃ to 538℃ ,and its pressure rises from 1MPa to 3.8MPa. So it' s essential for Power Plant to avoid shrouds damaged under the bad settings. This article uses the finite element simulation analysis software to draw the model of the shrouds, and analysis its temperature field, stress field and comprehensive stress field under the conditions of cold startup. Finding out the part with the most concentrated stress ,which is the most dangerous part during the whole startup.
机构地区 沈阳工程学院
出处 《汽轮机技术》 北大核心 2014年第6期425-428,共4页 Turbine Technology
关键词 中压缸 隔热罩 温度场 应力场 应力集中 pressure cylinder shrouds temperature field stress field stress concentration