摘要 根据制造核级阀门的有关标准,需对核级阀门电动执行机构进行湿热试验。将执行机构放入高低温湿热试验箱内进行湿热试验,试验后,未发现设备表面有腐蚀现象,随后在测试台上检测了电动执行机构的各项参数,全行程的运行参数均在规定范围内,执行机构的输出力矩较稳定,验证了核级阀门电动执行机构在湿热条件下的工作性能。 In accordance with the relevant standards of nuclear class valve, the damp heat test was carried, in order to assess the adaptability of nuclear-grade electric actuator in damp and hot environment, According to the required condition, the high-low temperature test-box was put into the damp heat test box to carry on the test. And then no signs of corrosion was found on the surface of actuator. The performance parameters of electric actuator was tested on the test table. All operation parameters are within the limitation. The test proved that the nuclear-grade electric actuator could work normally and the performance characteristics was not affected in damp and hot environment.
出处 《电站辅机》 2014年第4期35-37,共3页 Power Station Auxiliary Equipment
关键词 核电 电动 阀门 执行机构 湿热试验 性能 特性 测试 nuclear power electric-drive valve electric actuator damp heat test performance characteristics performance test
  • 相关文献

参考文献6

二级参考文献24

  • 1EJ/T1022.11-96,压水堆核电厂阀门电动装置[S].
  • 2EJ/T531-2001,核电厂安全级阀门驱动装置的鉴定[S].
  • 3成大先.机械设计手册第四版第3卷.北京:化学工业出版社,2003.
  • 4GB20044-2005 电气附件家用和类似用途的不带过电流保护的移动式剩余电流装置(PRCD)
  • 5JB839-75.《电工产品湿热试验》[S].[S].,..
  • 6JB833-75.《热带中小型电机》[S].[S].,..
  • 7JB834-75.《热带低压电器》[S].[S].,..
  • 8GB2423.4-81.《电工电子产品基本环境试验规程试验Db:交变湿热试验》[S].[S].,..
  • 9GJB4.6-83.《舰船电子设备环境试验方法交变湿热试验》[S].[S].,..
  • 10GJB150.9-86.《军用设备环境试验方法湿热试验》[S].[S].,..

共引文献29

同被引文献5

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部