基于载波移相的低压大电流APF系统应用研究

Research on Application of the Low-voltage and High-current APF Based on the Carrier Phase-shifted Technology
下载PDF
导出
摘要 大容量非线性负载产生含量丰富且比重较大的谐波电流源,导致电网畸变严重,低压大电流APF系统可以有效地进行就地补偿,有跟踪速度快、补偿精度高、长期稳定性好等一系列特点。从低压大电流APF系统本身讲述了系统优点分析、系统总体架构、系统核心控制算法、载波移相技术的采用以及系统实验效果和现场应用效果,较好地体现了系统的技术价值和市场推广价值。 Plentiful and heavy harmonic current source was introduced by powerful nonlinear load in lots of industrial organization, which also lead to serious distortion in the power supply system. Low-voltage and high-current APF system can delete the harmonic current at the source in order to prevent all the facilities in upper stream of grid from effect by the harmonic components. APF enjoys characteristics of quick response and target tracking, high compensation precision and good reliability. The topology, advantage, key algorithm and carrier phase- shifted application in the system were shown, moreover, the results in laboratory and field application also be illustrated, which demonstrate the value in technology and marketplaces.
出处 《电气传动》 北大核心 2014年第12期32-35,共4页 Electric Drive
关键词 大电流有源滤波器 谐波补偿 载波移相 high-current active power filter harmonic compensation carrier phase-shifted
  • 相关文献

参考文献5

  • 1吕文革,刘凯,谌季,杨彬.氯碱化工整流机组谐波的治理方法[J].中国氯碱,2011(7):4-6. 被引量:1
  • 2李红雨,雷万钧,卓放,王兆安.大功率有源电力滤波器研究[J].电力电子技术,2004,38(2):3-4. 被引量:8
  • 3Akagi H. Control Strategy and Site Selection of a Shunt Active Filter for Damping of Harmonic Propagation in Power Distribu- tion Systems [C]//IEEE Trans. on Power Delivery, 1997, 12 ( 1 ) :354-363.
  • 4Juan Carlos Montano Asquerino, Manuel Castilla Ibanez, An- tonio bapez Ojeda. Measurement of Apparent Power Compo- nents in the Frequency Domain [J]. IEEE Trans. on I.M., 1990, 39(4):583-587.
  • 5Lascu C, Asiminoaei L, Boldea I, et al. Frequency Response Analysis of Current Controllers for Selective Harmonic Com- pensation in Active Power Filters [J ]. IEEE Trans. on Industri- al Electronics, 2009, 56(2): 337-347.

二级参考文献5

  • 1Peng F Z, Kohata M,Akagi H. Compensation Characteristics of Shunt and Series Active Filter[A]. In Proceedings of 1992 Chinese-Japanes Power Electronics Conf.,Beijing[C]. 1992:381 -387.
  • 2Akagi H. New Trends in Active Filters for Power Conditioning [J].IEEE Trans.on Ind. Appl.,1996,32 (6): 1312-1322.
  • 3Akagi H. Control Strategy and Site Selection of a Shunt Active Filter for Damping of Harmonic Propagation in Power Distribution Systems [A].IEEE Trans.on Power Delivery[C].,1997,12(1):354-363.
  • 4卓放,周新,李可,雷万均,王兆安.模块化PWM主电路实现的大容量有源电力滤波器[J].电力系统自动化,2002,26(16):45-47. 被引量:17
  • 5王跃,杨君,王兆安,苏晓勃.电气化铁路用有源电力滤波器的控制系统[J].电力电子技术,2003,37(1):1-3. 被引量:11