摘要
以青奥体育馆为研究对象,针对建筑消防设计中防火分区面积、疏散距离因功能需要远远超出国家现行消防技术规范的常见问题,采取控制火灾荷载、加强防火分隔、完善消防设施等强化措施,并采用消防安全性能化评估方法评估方案的安全性。建立火灾模型,对烟气蔓延和人员疏散进行模拟计算,结果表明,现有的设计方案能够在火灾时保证人员的安全疏散。
Based on Youth Olympic Statium, fire design problems as over-large area of fire apartment and over-long evacuation distance were analyzed, the countermeasures were proposed as controlling fire load, strengthening fire separation and improving fire facilities, and performance-based assessment method was used. Set fire mode, simulate smoke spread and evacuation. The results showed that the existing fire design could assure people safety in fire.
出处
《消防科学与技术》
CAS
北大核心
2015年第1期52-54,共3页
Fire Science and Technology
关键词
青奥体育馆
安全疏散
防火分区
性能化评估
Youth Olympic Stadium
safety evacuation
fire apartment