Pulsed intense electron beam emittance measurement

Pulsed intense electron beam emittance measurement
下载PDF
导出
摘要 Recently we measured with the Modified Three Gradient Method(MTGM) the beam emittance of an injector constructed in 2012, which was designed to provide a 2.4 kA, 2.6 MeV electron beam. The MTGM is a non-intercept indirect method, which is based on the three gradient type measurements of beam profiles and subsequent data processing which helps to get the least square solution to the beam emittance. Beam profiles under different currents of guiding coil are measured using Cerenkov radiation given off by a piece of quartz glass in the beam tube, which is recorded with a CCD camera. MTGM Code is developed to realize the data fitting as well as beam transport simulation, in which both the σ matrix method and the numerical solution of root-mean-square beam envelope equation are used. The error is also analyzed. Recently we measured with the Modified Three Gradient Method(MTGM) the beam emittance of an injector constructed in 2012, which was designed to provide a 2.4 kA, 2.6 MeV electron beam. The MTGM is a non-intercept indirect method, which is based on the three gradient type measurements of beam profiles and subsequent data processing which helps to get the least square solution to the beam emittance. Beam profiles under different currents of guiding coil are measured using Cerenkov radiation given off by a piece of quartz glass in the beam tube, which is recorded with a CCD camera. MTGM Code is developed to realize the data fitting as well as beam transport simulation, in which both the σ matrix method and the numerical solution of root-mean-square beam envelope equation are used. The error is also analyzed.
作者 张卓 江孝国
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第6期18-23,共6页 核技术(英文)
关键词 电子束发射度 辐射测量 脉冲强流 修正三梯度法 CCD照相机 最小二乘解 间接方法 数据处理 Emittance measurements, High current beam, Modified three gradient method
  • 相关文献

参考文献13

  • 1Weiss M. The 1987 CERN Accelerator School, Aarhus, Den- mark, 1986, 162-163.
  • 2Ke J L, Zhou C G, Qiu R. High Power Laser Partic Beam, 2013, 8: 2067-2070.
  • 3Dong J M and Wang S M. Nucl Tech, 2005, 28: 435-437.
  • 4Bartch R R, Ekdahl C, Eylon S, et al. Beam emittance diag- nostic for the DARHT second axis injector, the 28th IEEE In- ternational Conference on Plasma Science and the 13th IEEE International Pulsed Power Conference (PPPS2001), Las Ve- gas, USA, Jun. 17-22, 2001, 1689-1692.
  • 5Bardy J, Bonnafond C, Devin A, et al. Status of AIRIX Align- ment and High Current Electron Beam Diagnostics, the 5th European Particle Accelerator Conference (EPAC96), Sitges, Barcelona, Jun. 10-14, 1996, 1588-1590.
  • 6Dai Z Y. Ph.D. Thesis, China Academy of Engineering Physics, 2003.
  • 7Guan Z. Calculated method. Beijing (CHN): Ysinghua Univer- sity Press, 1996.
  • 8Chen S E Time-resolved beam profile measurements of high- current, short-pulse electron beam. Report of Postdoctoral Work, China Academy of Engineering Physics, 2001.
  • 9Physics Manual Team. Physics manual. Fuzhou (CHN): Fujian People's Press, 1991, 825-827.
  • 10Li Q Y, Wang N C, Yi D Y. Numerical calculations. Wuhan (CHN): Huazhong Theory and Technology University Press, 1982, 97-105.