摘要 通过分析影响平板集热器集热效率和热损失的因素,对其结构和参数进行优化,设计出1种管板一体化吸热板的平板集热器,同时在透明面盖上增加增透膜并优化吸热板和面盖之间的距离。通过理论计算和试验的方法研究其集热性能,优化后的平板集热器截距效率相较普通平板集热器提高了7%,而热损系数减少了4.1%;热效率因子理论相对优化率为5.2%,实验相对优化率为4.2%;热迁移因子理论相对优化率为4.4%,实验相对优化率为4.8%。 The structure and parameters of flat-plate collector (FPC) were optimized by analyzing the factors influencing the heat efficiency and heat loss.A integral structure of tube and sheet was designed to improve the performance of FPC.Compared with the traditional FPC,the optimized one gains an increase by 7% of intercept efficiency and a decrease by 4.1% of heat loss coefficient.The relative rate of theoretical and experimental optimization for heat efficiency factor is 5.2% and 4.2%,respectively.The relative rate of theoretical and experimental optimization for heat removal factor is 4.4% and 4.8%,respectively.
作者 周炫 代彦军
机构地区 上海交通大学
出处 《建筑科学》 北大核心 2014年第12期85-88,共4页 Building Science
基金 国家科技支撑计划"采用复合工质的建筑构件化太阳能平板集热系统应用与示范"(2011BAJ03B01-03)
关键词 平板集热器 集热效率 热效率因子 热迁移因子 flat-plate collector heat efficiency heat efficiency factor heat removal factor
  • 相关文献

参考文献6

  • 1李戬洪,江晴.一种高效平板太阳能集热器试验研究[J].太阳能学报,2001,22(2):131-135. 被引量:33
  • 2焦青太.当今世界太阳能热水器的发展状况[J].建筑节能,2007,35(8):59-62. 被引量:13
  • 3夏柏林.整体式平板太阳能集热器集热性能研究与热迁移因子分析[D].上海:上海交通大学,2011.
  • 4张鹤飞.太阳能热蒯用原理与计算机模[M].西安:西北工业大学出版社,1990:93-106.
  • 5上海机械学院太阳能所.GB/T4271-2000平板型太阳集热器热性能试验方法[S].北京:中国标准出版社,2000.
  • 6ANSI/ASHRAE Standard. 93-2010, Methods of Testing to Determine the Thermal Performance of Solar Collectors[ S]. New York, 2010.

二级参考文献1

共引文献45

同被引文献42

引证文献6

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部