研究用高压釜消解-ICP-OES测定印刷线路板中重金属元素Pb,Cd及S的含量。结果表明,方法灵敏、快速、准确、操作方便,实用性强。Pb,Cd,S的回收率在96.0%-97.8%之间,相对标准偏差RSD〈5%。
The determination of Pb ,Cd and S content in coating drier by Inductively Coupled Plasma-Optical Emission Spectrometer(ICP-OES)with high press digustion is investigated. The result s show that this method is delicacy ,rapid , accurate ,easy to operate and practicable. The recoveries for the three element s are in the range of 96.0%-97.8%and relative standard deviation〈5%is achieved.