摘要 利用AL204型电子天平对氯型强碱性阴离子交换树脂进行10次平行试验,测定其含水量,并对测量的不确定度进行评估。通过建立数学模型,分别对由电子天平的分辨率引入的不确定度、电子天平的称量不准确引入的不确定度及电子天平的测量重复性引入的不确定度进行分析,最终确定含水量测定的不确定度主要影响因素是天平的重复性称量。 Using chloride type strongly basic anion exchange resin, by using the AL204 type electronic balance to do 10 times parallel test determination of moisture content, to assess the degree of uncertainty of measurement. Through the establishment of mathematical model, separately on the resolution, weighing accuracy and repeatability of measurement uncertainty of electronic balance, analysis of the three main sources of uncertainty. Ultimately determine the factors of uncertainty is the main impact of weighing repeatability balance.
出处 《内蒙古电力技术》 2014年第6期108-110,共3页 Inner Mongolia Electric Power
关键词 氯型强碱性阴离子交换树脂 含水量 不确定度 重复性称量 chloride type strongly basic anion exchange resin water content uncertainty repeated weighing
  • 相关文献

参考文献6

二级参考文献6

  • 1JJG99-2006《砝码检定规程》.全国质量密度计量技术委员会.
  • 2JJG1036-2008《电子天平检定规程》.
  • 3崔焕芳,王广珠,邵林,等.DL/T 807-2002火力发电厂水处理用201×7强碱性阴离子交换树脂报废标准[S].西安:国家电力公司热工研究院,2002.
  • 4JJF1059-1999.《测量不确定度评定与表示》.[S].,..
  • 5DL/T 519-2004,火力发电厂水处理用离子交换树脂验收标准[S].
  • 6谢昭明,周柏青.有机物污染离子交换树脂的复苏及应用[J].华北电力技术,2000(10):14-17. 被引量:14