期刊文献+

离心泵振动原因分析及解决措施 被引量:2

Cause analysis and solutions for centrifugal pump vibration
下载PDF
导出
摘要 由于安装存在问题,离心泵P008高液位启动后运行正常,当液位达到入口管线的顶端位置时,即开始剧烈振动,无法继续运行。为寻求产生振动的原因,从离心泵安装高度、集水池储量、吸水漩涡、管道配置4个方面进行了数据核实,最终确定振动原因是入口管线存在窝气区,引起振动。对此进行了基础及管线的改造,解决了设备的振动问题。 Due to installation problems,P008 centrifugal pump running normally with high level but violent vibration would occurwhen the liquid level reaches the top of the suction line and the pump had to be stopped. In order to find the causes of vibration,dataverification were conducted on mounting height of the centrifugal pump,water pool reserves,suction eddies and pipelinearrangement. The cause of the vibration finally determined was the existence of gas province in suction line. Foundation and pipelinemodification were performed and equipment vibration problem were solved.
作者 刘凤
出处 《炼油与化工》 2014年第6期31-33,62,共3页 Refining And Chemical Industry
关键词 离心泵 振动 储量 漩涡 centrifugal pump vibration reserve eddy
  • 相关文献

参考文献4

  • 1姚新华,何耀辉.立式离心泵电机滚动轴承故障振动分析诊断[J].设备管理与维修,2011(2):47-49. 被引量:2
  • 2戴传芳.给水排水设计手册第一册[M].北京:中国建筑工业出版社,1986:28-35.
  • 3成大先.机械设计手册第二卷[M].北京:化学工业出版社,2009:41-42.
  • 4戴传芳.给水排水设计手册第二册[M].北京:中国建筑工业出版社,1986:11-14.

共引文献2