对比观察纳米微泡与微米微泡在高强度聚焦超声消融新鲜离体牛肝中的增效作用

Comparison of high intensity focused ultrasound enhanced effect of nanobubbles and microbubbles in fresh bovine liver in vitro
下载PDF
导出
摘要 目的探讨纳米微泡与微米微泡在增效高强度聚焦超声(HIFU)作用中的差异。方法机械振荡低速离心法制备纳米微泡。分别采用0.2、0.5和0.8 ml的纳米微泡、Sono Vue微泡及PBS溶液联合HIFU消融离体牛肝。HIFU功率为180 W,辐照时间5 s,记录各次消融靶区凝固性坏死体积大小,并行统计学分析。结果各剂量下纳米微泡组与Sono Vue组消融的组织体积均大于PBS溶液组(P﹤0.05);随着纳米微泡组与Sono Vue组剂量的增加,其消融体积均明显增加,而各PBS组差异无统计学意义(P﹥0.05)。在相同的剂量下,纳米微泡组消融体积大于Sono Vue组(P﹤0.05)。结论纳米微泡及微米微泡均能显著增强HIFU的消融效果,在相同剂量条件下,纳米微泡较微米微泡能更好地提高HIFU的治疗效果。 Objective To investigate the difference in high intensity focused ultrasound enhanced effect of nanobubbles and microbubbles.Methods The nanobubbles were prepared using mechanical oscillation and low speed centrifugation method.The degassed bovine livers in vitro were respectively injected into 0.2 ml,0.5 ml and 0.8 ml of nanobubbles,microbubbles and PBS when HIFU exposure.HIFU ablation parameters were the following:acoustic power was 180 W,exposure duration was 5 s.After HIFU ablation,the volumes of coagulative necrosis were calculated and recorded.The data were analyzed using statistic method.Results The volumes of coagulative necrosis in bovine liver irradiated by HIFU after local injection of nanobubbles and microbubbles were larger than those of PBS using the same dose(P ﹤ 0.05).With dose increasement of nanobubbles and microbubbles,the volumes of coagulative necrosis increased,but the volumes of coagulative necrosis in different PBS groups were no significant differences(P﹥0.05).Moreover,the volumes of cougulative necrosis of nanobubbles were larger than those of microbubbles with the same dose(P﹤0.05).Conclusion The effect of HIFU ablation was distinctly enhanced with the use of nanobubbles and microbubbles.With the same dose,nanobubbles may be more efficient than microbubbles in HIFU therapy.
出处 《临床超声医学杂志》 2014年第12期797-799,共3页 Journal of Clinical Ultrasound in Medicine
基金 国家自然科学基金面上项目(81371578) 重庆市自然科学基金项目(cstc2013jcyj A10002) 重庆市卫生局医学科研计划重点项目(20131024) 重庆市博士后科研项目特别自助(Xm2014054)
关键词 微泡 纳米 微米 高强度聚焦超声 牛肝 离体 Microbubbles,nanometer,micrometer High intensity focused ultrasound Bovine liver,in vitro
  • 相关文献

参考文献3

二级参考文献17

  • 1Chuan-XingLi,Guo-LiangXu,Zhen-YouJiang,Jian-JunLi,Guang-YuLuo,Hong-BoShan,RongZhang,YinLi.Analysis of clinical effect of high-intensity focused ultrasound on liver cancer[J].World Journal of Gastroenterology,2004,10(15):2201-2204. 被引量:25
  • 2李发琪,马平,寇小琴,许杰,左国伟,王智彪.一种用于HIFU聚焦性能评价的仿组织透明体模[J].中国医学影像技术,2006,22(8):1262-1265. 被引量:12
  • 3Wang Z,Li F,Bai J,et al.A study of acoustic environment intissue of high intensity focused ultrasound.3rd InternationalSymposium on Therapeutic Ultrasound.Lyon:INSERM U.556,2003:68.
  • 4Lindner JR.Contrast ultrasound molecular imaging of inflamma-tion in cardiovascular disease.Cardiovasc Res,2009,84(2):182-189.
  • 5Ferrara KW,Borden MA,Zhang H.Lipid-shelled vehicles:En-gineering for ultrasound molecular imaging and drug delivery.AccChem Res,2009,42(7):881-892.
  • 6Kaufmann BA.Ultrasound molecular imaging of atherosclerosis.Cardiovasc Res,2009,83(4):617-625.
  • 7Tung YS,Liu HL,Wu CC,et al.Contrast agent enhanced ultra-sound thermal ablation.Ultrasound Med Biol,2006,32(7):1103-1110.
  • 8Stride EP,Coussios CC.Cavitation and contrast:The use of bub-bles in ultrasound imaging and therapy.Proc Inst Mech Eng H,2010,224(2):171-191.
  • 9Bailey MR,Couret LN,Sapozhnikov OA,et al.Use of overpres-sure to assess the role of bubbles in focused ultrasound lesionshape in vitro.Ultrasound Med Biol,2001,27(5):695-708.
  • 10Yu T,Wang G,Hu K,et al.A micro-bubble agent improves thetherapeutic efficiency of high intensity focused ultrasound:A rab-bit kidney study.Urological Research,2004,32(1):14-19.

共引文献51

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部