摘要
在分析铜头电站2F机组调速器抽动的基础上,介绍了故障的过程及处理,探讨了产生的原因,逐个进行了检查排除和有针对性的处理,消除了调速器抽动现象。
Abnormal pulse is observed in the operation of governor in 2F turbine unit in Tongtou Hydropower Station. Possible reasons of this fault are analyzed and corresponding treatment measures are taken.With these measures, the fault has been successfully eliminated.
出处
《水电与新能源》
2015年第1期72-73,共2页
Hydropower and New Energy
关键词
混流式机组
调速器
主配压阀
反馈传感器
接力器抽动
Francis turbine unit
governor
main distributing valve
feedback sensor
servomotor pulse